ETA-ECS3 

Power Sequencer & Conditioner

 

  

 

•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
 

ETA Systems. 

•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the  
 

AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in  

 

electric shock or fire.

• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric  

 

shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects  

 

on the power cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic  

 

disaster may result. 

• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.

 

 
•   Installation of this product must be done by a certified electrician for a permanently connected apparatus provided neither with an  
 

all-pole mains switch nor an all-pole circuit breaker. A readily accessible disconnect device shall be incorporated in the building    

 

installation power wiring. The installation shall be carried out in accordance with all applicable installation rules in accordance with all  

 

applicable federal, state, and local laws, regulations, and safety codes and ordinances. 

•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or  
 

steam are present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

 
•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In    
 

addition, the product itself may fall and cause injury and property damage. 

•  Contact ETA Systems for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat  
 

buildup and fire. 

•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or  
 

inside the wall outlet. 

•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

CAUTION – WHEN INSTALLING THE PRODUCT

WARNING – WHEN THE DEVICE IS IN USE

CAUTION – WHEN THE DEVICE IS IN USE

 

Содержание ETA-ECS3

Страница 1: ...om Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner ETA ECS3 Power Sequencer Conditioner ...

Страница 2: ...9 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features 6 Applications 6 Front Panel 7 Rear Panel 9 Installation 10 Troubleshooting 10 AC Power Cord Retainer System 11 Specifications 12 Warranty 16 ...

Страница 3: ...ination to avoid injury from tip over 13 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unp...

Страница 4: ...g so may result in fire or electrical shock Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage Installation of this product must be done by a certified electrician for a ...

Страница 5: ... energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem the ETA ECS3 features Dual Clamping Suppression technology DCS If a spike intrudes the AC system the ETA ECS3 incoming AC Mains has special suppression circu...

Страница 6: ...on 15A Indicated by Breaker Open Indicator Front Mounted Pull out LED Light With 2 Position Dimmer Rear Mounted XLR Connector for 12VDC LED Lamp Lamp sold separately Atlas Power model AP GNL18 External Switch Sequence Trigger Activation External DCV Sequence Trigger Activation 5 24VDC 12VDC Sequence Trigger Output for Optional External AC Outlet AC Power Cord Retainer APPLICATIONS The ETA ECS3 was...

Страница 7: ...tion circuitry but will not be shut off by the EVS circuit 2 AC Mains Breaker The 15A rated breaker will open if the combined continuous current draw of all AC outlets exceeds 15A Note In audio applications peak current demands commonly exceed the continuous current ratings on AC outlets Note The breakers are designed to exceed their rating for a short period of time If the breaker is tripped to r...

Страница 8: ...hes under several AC Mains fault situations that are listed below Normal operating voltages for AC Mains voltage is considered to be between 108VAC and 125VAC Any voltages exceeding those parameters are considered a risk to damage equipment plugged into the ETA ECS3 High AC Line Mains The Abnormal Voltage LED will flash between 128VAC 132VAC indicating possible damage may occur to equipment due to...

Страница 9: ...nalog filter outlets If more high power outlets are needed or if 15A is not enough current to support your power requirements you can use the 24VDC trigger to activate an additional power outlet such as the ETA 20SH Contact ETA Systems for AC outlet options 5 XLR Light Socket A 12VDC XLR light socket is to provide power for the optional Atlas Power AP GNL18 light 6 Light Socket Power Switch This s...

Страница 10: ...l Voltage indicator is illuminated the Volt Meter is Flashing and you hear a buzzer from the unit Possible Cause The AC Mains Voltage exceeded 132VAC or the voltage dropped below 101VAC Action Needed Measure the AC mains before the ETA ECS3 If the voltage is between 117VAC and 123VAC you may proceed to reset the ETA ECS3 by restarting the start up sequence Note It is important to have all equipmen...

Страница 11: ...st be done by a certified electrician for a permanently connected apparatus provided neither with an all pole mains switch nor an all pole circuit breaker A readily accessible disconnect device shall be incorporated in the building installation power wiring The installation shall be carried out in accordance with all applicable installation rules in accordance with all applicable federal state and...

Страница 12: ...08mm Type Connector DC Output 12VDC 100mA Output Paralleled to Sequencer Section 3 Timing LED Light Socket XLR Socket to Provide 12VDC for Optional 16 Gooseneck Lamp AP GNL18 LED Light Switch Two Position On Off Grounding Terminal Hand Screw Type Terminal to Chassis Ground AC Mains Power Cord 9 3 Meters 14 gauge Technical Data Current Rating 15 amps Power Consumption 12 watts Operating Voltage 102...

Страница 13: ... 13 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Страница 14: ... 14 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Страница 15: ... 15 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS3 Power Sequencer Conditioner NOTES ...

Страница 16: ... below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be ...

Отзывы: