Do  not  wear  metallic  rings,  watchbands,  ear,  nose,  or  lip  rings  or  other 
metallic devices while installing or troubleshooting photovoltaic systems. 

Use appropriate safety equipment (insulated tools, insulating gloves, etc.) 
approved for use on electrical installations. 

 

Observe the instructions and safety precautions for all other components used 
in the system, including wiring and cables, connectors, DC-breakers, mounting 
hardware, inverters, etc.   

 

Use only equipment, connectors, wiring and mounting hardware suitable for 
use in a photovoltaic system.   

 

Always use the same type of module within a particular photovoltaic system.   

 

Under  normal  operating  conditions,  PV  modules  will  produce  currents  and 
voltages that are different from those listed in the data sheets. The values in the 
module data sheets are collected under very specific circumstances known as 
Standard Test Conditions.   

 

Short-circuit current and open-circuit voltages should be multiplied by a factor 
of 1.25 when determining component voltage ratings, conductor ampacity, 
fuse sizes and size of controls connected to the module or system output. An 
additional  multiplying  factor  of  125  percent  (80  percent  de-rating)  may  be 
applicable. 

 

Only connect modules with the same rated output current in series. If modules 
are connected in series, the total voltage is equal to the sum of the individual 
module voltages. The maximum system voltage for double glass module type is 
1500V(IEC), for roof use, the maximum system voltage must not exceed 1000V 
according to National Electrical Code. 

 

Only connect modules or series combinations of modules with the same 
voltage in parallel. If modules are connected in parallel, the total current is 
equal to the sum of individual module or series combination currents.   

3.2

 

General installation notes 

 

The junction box has a breather port which must be mounted facing downward 
and cannot be exposed to the rain. The junction box should be on the higher 
side  of  the  module  when  it  is  mounted  in  order  to  orient  the  breather  port 
correctly.   

 

Do not lift the module by grasping module's junction box or electrical leads.   

 

Do not stand or step on the module.   

 

Do not drop the module or allow objects to fall on the module.   

 

Do not place any heavy objects on the module.   

 

Do not scratch the glass surface. 

 

Prior to installation, do not store modules outdoors or in a damp environment. 

 

Inappropriate transport and installation may damage the module glass. 

3.3

 

Fire rating 

 

The  fire  rating  for  this  module  is  only  valid  when  the  product  is  installed  as 
specified in the mechanical mounting instructions in this document. 

Содержание ET-M660BH BB Series

Страница 1: ...www etsolar hk INSTALLATION MANUAL ET Solar Series Module Installation Safety instructions Maintenance...

Страница 2: ...www etsolar hk Version 2021Q1...

Страница 3: ...ting the proper mounting structure and hardware 4 4 2 Mounting methods 4 4 2 1 Mounting with bolts 5 4 2 2 Mounting with clamping hardware 5 4 2 3 Installation position and static loads 6 5 Electrical...

Страница 4: ...ompliance with this installation instruction may result in property damage and or physical injury ET Solar will not be liable for compensation of any loss or injury caused by this type of non complian...

Страница 5: ...85 If modules are to be installed in areas where the temperature may go outside the above range please consult with ET Solar before installation Do not attempt to disassemble the module and do not re...

Страница 6: ...ble Only connect modules with the same rated output current in series If modules are connected in series the total voltage is equal to the sum of the individual module voltages The maximum system volt...

Страница 7: ...lecting the location Tilt Angle Select a suitable location for installation of the module For optimum performance the module must be facing true south in northern latitudes and true north in southern...

Страница 8: ...r with spring washers and flat washers in eight symmetrical locations on the pv module The applied torque value should be big enough to fix the modules steadily Please find detailed mounting informati...

Страница 9: ...www etsolar hk 6 4 2 3 Installation position and static loads...

Страница 10: ...f PV module array is connected to earth during all PV system installations That will keep optimal performance of PV Power Plants which are located in a hot high humidity climate and high Maximum Syste...

Страница 11: ...ng through the hot spot cells in order to prevent module over heated and performance loss Notice bypass diode is not the overcurrent protection device If the diode is suspected to be defective the ins...

Страница 12: ...used in the system Please refer to cleaning manual for specific contents 6 2 The visual inspection of the modules Inspect the modules visually to find if there are appearance defects especially wheth...

Страница 13: ...xperience and is believed to be reliable but such information including product specification without limitations and suggestions does not constitute a warranty expressed or implied ET Solar reserves...

Страница 14: ...www etsolar hk 11 Sheet 2 solar cell type 158 75mm...

Страница 15: ...www etsolar hk 12 Sheet 3 solar cell type 156 75mm mono si poly si Sheet 4 solar cell type 182mm For module specifications or datasheets please download from www etsolar hk...

Страница 16: ...NG LIMITED Room 01 21 F XINGFA Commercial Building 9th Tobacco Factory Street Mong Kok HongKong Tel 86 510 85382358 Fax 86 510 85382358 Mail support etsolar hk www etsolar hk ET SOLAR INC 4900 Hopyard...

Отзывы: