Ext. Control: Computer
22
ET System electronic GmbH
Example:
#1,ID
#22,GTR
#ALL,GTL
The status word can be read with the command
<STB>
or
<*STB?>
. The following functions are assigned to the bits:
Bit
Function
D15
Parity error
D14
Over run error
D13
Framing error
D12
Timeout error
D11
n/a
D10
n/a
D9
n/a
D8
n/a
D7
Parity enable
D6
Parity mode (1 = odd, 0 = even)
D5
Stop bit (1 = 2 Stop bits; 0 = 1 Stop bit)
D4
Data format (1 = 8 bit; 0 = 7 bit)
D3
n/a
D2
Table
D1
Table
D0
Table
Table: Error messages
D2
D1
D0
Error
0
0
1
Syntax
0
1
0
Command
0
1
1
Range
1
0
0
Unit
1
0
1
Hardware
1
1
0
Read
Interface parameters are configured via software using the command
<PCx>
. The settings can be saved with the
command
<SS>
.
Interface Reconfiguration
In case, the user has forgotten the active setup, there are two ways of reconfiguring the interface:
sending the command
<PCx>
from one of the other interfaces
using the display to configure the interface
Interface Parameters