5.8
Harmonic and inter-harmonic simulation
5.8.1
Harmonic simulation
EAC-4Q-KS series provide complete GUI software, which can edit up to the 40th harmonic and
inter-harmonics.
Test steps:
Click "Sequence Mode" to enter the panel, firstly set the basic operating parameters (such as
output voltage, frequency). Click "Apply"→"Power On"→"Output On" in turn, the power supply
is on. Check the harmonic selection box (Figure 5-15①), click the A/B/C phase harmonic
simulation button (Figure 5-15③), the harmonic setting panel of each order will automatically
pop up, then the user can set the harmonic. After setting the parameters such as waveform
angle and content, check the corresponding boxes and click "Setting" → "Apply" in turn.
To cancel the harmonic simulation, click the A/B/C phase harmonic simulation button (Figure
5-15③), click "Clear" on the pop-up panel to clear all parameters, and then click "Setting" →
"Apply". Finally, uncheck the harmonic selection box.
Figure 5-15 Harmonic Edit-1
Table 5-6
Number
Name
Note