5.7.2
AC
The KS series allows the generation of AC voltage, current and waveform, which can simulate the
real AC circuit conditions. Three-phase independent programmable control and have high
accuracy.
Test steps:
Click "Sequence Mode" to enter the sequence mode test panel, select AC+DC output mode
(AC+DC) on the right side of the panel (Figure 5-13①), the user can select different operating
modes (CV/CC) according to the test requirements, and set the AC voltage/current (Figure
5-13②). After setting the parameters, click "Apply"→"Power On"→"Output On" in turn, the
power supply is on and outputs AC voltage/current.
IMPORTANT INFORMATION
When the DC offset is not set, the default is AC output mode.
IMPORTANT INFORMATION
In AC output mode, the three phases are independently programmable. If the -1P
option is added, the output AC current range will be expanded. For example, in
EAC-4Q-KS 45-300-50, the standard output AC current is 50A/phase, if the -1P
option is added (Add single phase output), after changing the corresponding
wiring, the maximum single-phase AC current can be output 150A.
(when related to wiring issues, please combine 2.2.2 and 2.2.3)
5.7.3
DC
The KS series allows the generation of DC voltage, current and waveform.
Test steps:
Click "Sequence Mode" to enter the sequence mode test panel, select the DC output mode (DC)
on the right side(Figure 5-14①), the user can select different operating modes (CV/CC)
according to the test requirements, and set the DC voltage/ Current (Figure 5-14②). When the
parameter setting is completed, click "Apply"→"Power On"→"Output On" in turn, the power
supply is on and outputs DC voltage/current.
IMPORTANT INFORMATION
In the DC output mode, only need to set the voltage/current of a certain phase, and
it will be the output DC voltage/current. If the power supply adds the -1P option,
the three-phase parameters (L1, L2, L3) need to be set at the same time. For
example, in EAC-4Q-KS 45-300-50, the standard output DC current is 25A/phase, if
-1P option is added (Add single phase output), after changing the corresponding
wiring, the maximum output DC current will be 75A.
(when related to wiring issues, please combine 2.2.2 and 2.2.3)