background image

13

CV

Name

Description

Range

Default

63

Sound  volume

Master volume control for all sounds.

0 - 192

129

64

Brake sound threshold «Brake On»

If the actual loco speed step is smaller than or equals the value indicated here, the brake 

sound is triggered. 

0 - 255

44

65

Brake sound threshold «Brake Off»

If the actual loco speed step is smaller than the one indicated here (up to 255), the brake 

sound will be switched off again. .

0 - 255

03

66

Forward Trim

Divided by 128 is the factor used to multiply the motor voltage when driving forward. 

The value 0 deactivates the trim.

0 - 255

128

67-94 Speed table

Defines motor voltage for speed steps. The values „in between“ will be interpolated.

0 - 255

-

113

Power Fail Bypass

The time that the decoder bridges via the PowerPack after an interruption of voltage. 

Unit: A multiple of 0.032768 sec. See section 6.12.2.

0 - 255

101

116

Slow speed BEMF Sampling period

Frequency of BEMF measurement in 0.1 milliseconds at speed step 1

50 - 200

35

117

Full  speed BEMF Sampling period

Frequency of BEMF measurement in 0.1 milliseconds at speed step 255

50 - 200

150

118

Slow speed BEMF Measurement gap Min

Length of the BEMF measuring gap in 0.1 milliseconds at speed step 1

10 - 20

15

119

Full  speed BEMF Measurement gap Max

Length of the BEMF measuring gap in 0.1 milliseconds at speed step 255

10 - 20 

20

124

Extended Configuration #2

Additional important settings for LokSound Decoders

-

16

Bit

Description

Value

0

Bi-directional bit: Keep driving direction when changing direction.

Do not keep driving direction.

1

0

1

Disable decoder lock with CV 15 / 16

Enable decoder lock with CV 15 / 16

0

2

2

Disable prime mover startup delay

Enable prime mover startup delay

0

4

3

Disable serial protocol 

Enable serial protocol

0

8

4

Enable Output AUX9  (LokSound 5 H0 only)

Enable Wheel Sensor input (LokSound 5 H0 only)

0

16

5

Motor Overload Protection

Motor is not switched off when blocked.

Motor is switched off for a few seconds when blocked to avoid 

burnout

0

32

6

Disable Automatic parking Brake

Enable Automatic parking Brake (EMK Braking)

0

64

7

Reserved

128

125

Starting voltage Analog DC

0-255

70

126

Maximum speed Analog DC

0-255

120

Programming table - List of most important CVs

Содержание GHB DD-1

Страница 1: ...LokSound 5 DCC Instruction manual GHB DD 1 P N 99440...

Страница 2: ...s 9 5 1 2 Read out addess 9 6 Support and Assistance 15 Copyright 1998 2020 by ESU electronic solutions ulm GmbH Co KG Electri cal characteristics and dimensions are subject to change without prior no...

Страница 3: ...l functions such as motor control control of all lighting functions and all sound and special sound functions The decoder supports DCC with RailComPlus It can also be used on analogue DC systems The D...

Страница 4: ...restriced Driving functions forward backward backward Light changes Motor sounds automatically For analogue operation you can use any DC power supplies Please note that a trouble free operation with e...

Страница 5: ...ehaviour of the decoder 3 1 2 Standardization in the NMRA The NMRA National Model Railroad Association has defined which CVs determine certain parameters of a decoder The DCC standard allocates fixed...

Страница 6: ...okmaus2 Lenz digital plus Lenz compact only support the values 1 99 as short addresses 3 4 1 2 Extended Address Programming on the Main also called Operations Mode pro gramming enables you to program...

Страница 7: ...set in CV 4 Permitted values are 0 no delay to 63 The times set in these CVs work speed dependant Therefore the acceleration distance and the brake distance are longer at high speeds In other words t...

Страница 8: ...g into account the programmed deceleration 3 4 3 3 Lenz ABC Brake Mode LokSound decoder support the ABC braking technique introduced by Lenz In order to use this function a group of anti parallel diod...

Страница 9: ...established as follows esired address 4007 minus first address in the address range 3840 equals value for CV 18 167 167 is therefore the value to be entered in CV 18 Thus your de coder is now program...

Страница 10: ...ncy Motor PWM frequency as a multiple of 1000 Hz 10 50 40 13 Analogue mode F1 F8 Status of functions F1 to F8 in analogue mode 0 255 128 Bit Description Value 0 Function F1 1 1 Function F2 2 2 Functio...

Страница 11: ...ant information some of which are only relevant for DCC operation 14 Bit Description Value 0 Normal direction of travel Reversed direction of travel 0 1 1 14 speed steps DCC 28 or 128 speed steps DCC...

Страница 12: ...w is active 0 255 10 52 Load Control param K for slow driving K component of the internal PI controller for the low speed steps 0 255 15 53 Control Reference voltage Defines the Back EMF voltage which...

Страница 13: ...od Frequency of BEMF measurement in 0 1 milliseconds at speed step 255 50 200 150 118 Slow speed BEMF Measurement gap Min Length of the BEMF measuring gap in 0 1 milliseconds at speed step 1 10 20 15...

Страница 14: ...l be recognised 4 32 12 155 162 Notch Points Notch Point 1 Notch Point 8 The internal speed step where the diesel engine sound notches to the next Notch Not for all sound projects 0 255 163 Sound CV9...

Страница 15: ...d also check our website for more information You will find many hints under Support FAQ and even feedback from other users that may help you with your particular question Of course we will always ass...

Страница 16: ...16 Instruction manual LokSound 5 GHB DD 1...

Отзывы: