INPUT / OUTPUT UNIT
19
Channel indicators I1~I16 indicate communication condition of each channel.
Tab 6.10 ER-1311 Channel indicators definitions
Light condition
Definition
Light off
The channel is abnormal.
Light on
The channel is normal.
6.2.3.
Technical Parameters
Technical parameters of digital input module are show in the following table:
Tab 6.11 ER-1311 technical parameters
Parameters
Description
Number of Channels
16
Rated Voltage
24VDC (
﹣
15
%
/
﹢
20
%
)
“0” Signal Voltage
≤5V
“1” Signal Voltage
≥12V
Input Current
≤5mA
Input Filter
5ms
Power Supply Mode
TBUS ( No external wiring is required.)
TBUS Consumption Current
≤50mA
Networking Mode
Set module address by dial switch
Electrical Isolation
Isolation voltage 2kV
Size (W×H×D)
112mm×113mm×22.5mm
Weight
About 200 g
Working Temperature
0
℃
~40
℃
Storage Temperature
﹣
25
℃
~55
℃
Relative Humidity
50
%
~95
%
, no condensation
Relative humidity not less than 95
%
at 0
℃
Relative humidity not less than 50
%
at 40
℃
Guide Rail Installation
35mm standard U type guide rail, horizontally installed.
Anti-shock and vibration performance
Consistent with EN 60068-2-6 / EN 60068-2-27/29
Anti electro-magnetic interference/radiation performance
Consistent with EN 61000-6-2 / EN 61000-6-4
Protection Level
IP20
Hot Swap
DI signal support hot-swapping.
TBUS does not support hot-swapping.
6.3.
Digital Output: ER-2341
6.3.1.
Functions
Function of digital output module: receive and execute instructions from the coupler by sending logical data from the coupler
to executive elements.
Содержание ERSA-4C
Страница 1: ...ESTUN ERSA 4C Cabinet E 0301EN 01 MAINTENANCE MANUAL...
Страница 2: ...ESTUN ERSA 4C Cabinet MAINTENANCE MANUAL E 0301EN 01...
Страница 45: ...CONNECTION 31 10 COMMUNICATION CONNECTION Fig 10 1 Communication connection between controller and servo motors...
Страница 55: ...Revision Record 41 Revision Record Revision Date Contents 01 2017 11...
Страница 56: ......