background image

9

3-wire connection: Direct wire

Use this method only if local codes permit connecting ground 
conductor to neutral supply wire.

1. Loosen (do not remove) the hex washer head screws and 

insert the neutral (white) wire under the screw clamp at the 
bottom of the center position terminal connector.

2. Insert the other 2 wires (lines 1 and 2) under the other 2 screw 

clamps.

3. Securely tighten the hex washer head screws to 

35 lbs-in. (4.0 N-m) minimum torque to make a proper 
electrical connection.

4. Tighten the locking ring of the conduit connector.

5. Replace the terminal block cover.

Verify Anti-Tip Bracket Location

1. Pull drawer open to first stop position. Lift front of drawer to 

clear white wheels in drawer guides. Remove drawer and set 
it aside on a protected surface.

2. Making sure the anti-tip bracket is installed:

Look for the anti-tip bracket securely attached to floor.

Slide range back so rear range foot is under anti-tip 
bracket.

3. If installing the range in a mobile home, you must secure the 

range to the floor. Any method of securing the range is 
adequate as long as it conforms to the standards in the 
“Location Requirements” section.

Level Range

1. Place rack in oven. Place level on rack and check levelness of 

range, first side to side; then front to back.

If range is not level, pull range forward until rear leveling leg is 
removed from the anti-tip bracket.

On Ranges Equipped with Storage Drawers:

Use 

³⁄₈

" drive ratchet and channel lock pliers to adjust leveling 

legs up or down until range is level. Push range back into 
position. Check that rear leveling leg is engaged in anti-tip 
bracket.

On Ranges Equipped with Warming Drawers:

Use channel lock pliers to adjust leveling legs up or down 
until range is level. Push range back into position. Check that 
rear leveling leg is engaged in anti-tip bracket.

NOTE: Range must be level for satisfactory baking 
conditions.

2. Replace the storage drawer (and warming drawer on some 

models).

A. Line 1
B. Ground-link

C. Hex washer head screw
D. Silver-colored terminal 

block screw

E. Neutral (white) wire

F. Line 2

G. UL listed strain relief 

and power supply 
cable

A. Insert wire under screw clamp.
B. Hex washer head screw

A

B

C

D

E

F

G

A

B

Содержание RF265LXTB

Страница 1: ...potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provid...

Страница 2: ...m beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip...

Страница 3: ...he ground path is adequate Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest editi...

Страница 4: ...be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit...

Страница 5: ...nt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm...

Страница 6: ...e cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief scr...

Страница 7: ...t the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to...

Страница 8: ...icles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from t...

Страница 9: ...secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange 1 Place rack in oven Place level on...

Страница 10: ...ualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For pow...

Страница 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge...

Страница 12: ...W10141166A 2007 All rights reserved 7 07 Printed in U S A...