background image

4

Dryer Dimensions

*Most installations require a minimum 5½" (14 cm) clearance 

behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”

Minimum installation spacing for recessed area or closet 
installation

The dimensions shown following are for the minimum spacing 
allowed.

Additional spacing should be considered for ease of 
installation and servicing.

Additional clearances might be required for wall, door and 
floor moldings.

Additional spacing of 1" (2.5 cm) on all sides of the dryer is 
recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.

Companion appliance spacing should also be considered. 

Mobile Home - Additional Installation Requirements

This dryer is suitable for mobile home installations. 
The installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280).
Mobile home installations require:

Metal exhaust system hardware which is available for 
purchase from your dealer.

Mobile Home Installation Kit Part #346764, see “Tools and 
Parts” section for ordering information.

Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.

A. Small Opening Side-Swing Door
B. Large Opening Side-Swing Door

C. Wide Opening Side-Swing Door
D. Wide Opening Hamper Door

 

   

 

   

   

 

   

43

³⁄₈

"

(110 cm)

*26"

(66 cm)

29"

(73.66 cm)

A

15¼"

(38.74 cm) 43

³⁄₈

"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

B

22 ¾"

(57.8 cm)

43

³⁄₈

"

(110 cm)

13 ¾"

(34.9 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

D

43

³⁄₈

"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

C

22 ¾"

(57.8 cm)

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

 

A

B

C

    18"
(45.7 cm)

    1"
(2.5 cm)

       29"
(73.66 cm)

        1"
(2.5 cm)

        1"
(2.5 cm)

14" max.
(35.6

 

cm)

   27¾"
(70.5 cm)

5½"
 (14 cm)

  48 in.  
(310 cm  )

2

2

  24 in.
(155 cm  )

2

2

       3"
(7.6 cm)

       3"
(7.6 cm)

Содержание EGD4100SQ

Страница 1: ...ll safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol al...

Страница 2: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants In the State of Massachusetts the following installation instructions apply Installations and repairs ...

Страница 3: ...slope of 1 2 5 cm under entire dryer If slope is greater than 1 2 5 cm install Extended Dryer Feet kit Part No 279810 Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level Do not operate your dryer at temperatures below 45ºF 7ºC At lower temperatures the dryer might not shut off at the end of an automatic cycle Drying times can be e...

Страница 4: ... must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Mobile home installations require Metal exhaust system hardware which is available for purchase from your dealer Mobile Home Installation Kit Part 346764 see Tools and Parts section for ordering information Specia...

Страница 5: ...Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk ...

Страница 6: ...l gas do not use copper tubing flare x NPT adapter fitting between dryer pipe and approved tubing Lengths over 20 ft 6 1 m should use larger tubing and a different size adapter fitting If your dryer has been converted to use L P gas L P compatible copper tubing can be used If the total length of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint compounds that resist the acti...

Страница 7: ...ted when the dryer is in its final position Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance An exhaust hood should cap the vent to prevent rodents and insects from entering the home Exhaust hood must be at least 12 30 5 cm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes etc I...

Страница 8: ...st and most direct path outdoors Plan the installation to use the fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking Avoid 90º turns when possible 2 Determine vent length The maximum length of the exhaust system depends upon The type of vent rigid metal or flexible metal The number of elbows used Type of hood Reco...

Страница 9: ...rner posts until it is close to its final location Leave enough room to connect the exhaust vent 6 Once connection is made and dryer is in final location remove corner posts and cardboard For mobile home use Gas dryers must be securely fastened to the floor Mobile home installations require a Mobile Home Installation Kit For ordering information please reference your Dryer User Instructions Level ...

Страница 10: ...a 4 10 2 cm clamp 2 Move dryer into final position Do not crush or kink vent Make sure dryer is level 3 On gas models Check to be sure there are no kinks in the flexible gas line Reverse Door Swing Optional You can change your door swing from a right side opening to a left side opening if desired Reversible Large Side Swing Door 1 Place towel A on top of dryer to protect surface 2 Open dryer door ...

Страница 11: ...rt the door strike you removed in Step 8 in hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 11 Close door and check that door strike aligns with door catch C If needed slide door catch left or right within slot to adjust alignment Complete Installation 1 Check to be sure all parts are now installed If there is an extra part go back through the ...

Страница 12: ...8562589 2004 All rights reserved Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A 4 04 Printed in U S A ...

Отзывы: