GSM-INTERCOM OPERATION MANUAL
V20170702
• To add a number, the command is the following:
#PWD123456#WHL01=5553143815
Acknowledge
would
be
:
WHL01
SET
TO
5553143815
OK
Where 01 is the position in the list and (555) 314-3815 is the number enabled.
Please note that it is only possible to program up to a maximum of 10 digits for each number.
• To check which is the number in a place of the list:
#PWD123456#WHL01?
Acknowledge
:
WHL01
IS
61143815
OK
• To erase a number:
#PWD123456#WHL01=0000000
(or you can write over it another number you wish to add)
Acknowledge :
WHL01
SET
TO
00000000
• To erase all WHL numbers
#PWD123456#WHL=RESET
#QUERY
Query
the
phone
number
in
the
WHL
list.
Query the phone number in the position of the WHL list,Special phone list or Alarm phone list
#PWD123456#QUERY=143535353
Acknowledge
: QUERY
RESULT:
143535353
AT
WHL004
#ACM
Safety
control
or
free
control
mode
setting.
#PWD123456#ACM=ON
#PWD123456#ACM=OFF
ACM=OFF, Then any number can open the device through a phone call
ACM=ON, Then only the authorized number can control the device through a phone call
#GOT
Relay
delay
time.
(Only
for
NO.1
Relay)
When setting up the GOT Timer, first you also need to setup the timer multiplier at millisecond or second
or minutes.
#PWD123456#GOT5000:MILLISECOND
#PWD123456#GOT500:SECOND
#PWD123456#GOT500:MINUTE
This command is useful in case you need to keep the Relay output working longer. The standard time is 5
seconds (5000 ms). You can change it with the GOT command.
With the above command the delay time has been set to 5000 ms (5 seconds).
You can check what the current relay output delay time is with the command
#PWD123456#GOT?
Acknowledge
:
DELAYTIME
IS
05000
MS