Essilor CS pola 600 Скачать руководство пользователя страница 4

The complete user manual is available on a web space. To access, please scan the QR code below
using a dedicated application.

Le manuel utilisateur complet est disponible sur un espace web. Pour y accéder veuillez scanner 
le QR code ci-dessous à l'aide d'une application dédiée.

1. I

MPORTANT

This   product   may   malfunction   if   exposed   to   electromagnetic   interference   generated   by   cell   phones,
transceivers, radio-controlled toys, etc. Be sure to avoid bringing such items into close contact with the
product.

The information in this publication has been carefully checked and is believed to be entirely accurate at the
time of publication.

The manufacturer assumes no liability, however, for possible errors or omissions, or for any consequences
resulting from the use of the information contained herein. The manufacturer reserves the right to make
changes to its products or product specifications at any time and without prior notice, and is not required to
update this documentation to reflect such changes.

2. O

UTLINE

 

OF

 

PRODUCT

 

OVERVIEW

The CSPOLA600 / CSPOLA600C is an automatic stand-alone visual chart system. It displays a broad range of
charts on an LCD panel, including red /green for eye optometry.

The CSPOLA600 / CSPOLA600C can be rotated either using either a cabled or wireless remote control, or by
the Essilor APH550.

The chart rotation for CSPOLA600 / CSPOLA600C can be performed by either wired or wireless remote
control or by external devices by control box of digital phoropter.

Unlike existing chart projectors, the CSPOLA600 / CSPOLA600C is able to provide a wider range of charts
(more than 100 types of general and special charts) on an LCD panel. Furthermore, the product can be
adjusted at patient level so that precise examinations can be carried out. 

CSPOLA600 / CSPOLA600C - Polarized visual chart system > V5 - 03-2018

6

U

SER

 

MANUAL

> I. I

NTRODUCTION

Содержание CS pola 600

Страница 1: ...www essilor instruments com User manual...

Страница 2: ...15 IV NOTES FOR USING THE INSTRUMENT 17 V CONFIGURATIONS 19 VI INSTALLATION 21 1 Viewing distance LCD display position 22 VII TEST METHOD 23 VIII REMOTE CONTROL FUNCTION 29 1 General function 30 2 Sli...

Страница 3: ...I INTRODUCTION...

Страница 4: ...right to make changes to its products or product specifications at any time and without prior notice and is not required to update this documentation to reflect such changes 2 OUTLINE OF PRODUCT OVER...

Страница 5: ...CSPOLA600C is a class I medical device type B This device is compliant with marking Expected useful life 7 years Date of first marking 2013 USER MANUAL I INTRODUCTION 7 CSPOLA600 CSPOLA600C Polarized...

Страница 6: ...II SAFETY INFORMATION...

Страница 7: ...ces have been placed appropriately within the text of this manual to highlight safety related information or information requiring special emphasis All users operators and maintainers must be familiar...

Страница 8: ...d in the appropriate user s or service manual Useful information for the user D C current Polarity Indicates the obligation to collect and separate disposal of electrical and electronic equipment at t...

Страница 9: ...ecially metal Don t disassemble the product or open The warranty is void Be careful not to close the fan located on the lateral or back side of the equipment Don t plug the AC power cord into the outl...

Страница 10: ...that the following requirements have been fulfilled 1 the electrical installation in the respective room is consistent with the specifications stated in this manual and 2 this equipment is used operat...

Страница 11: ...III FEATURES...

Страница 12: ...ight dark places Random function Random feature The eye test may be performed with changes to the positions and arrangement of the figures and letters as well as to the Landolt ring Snellen and Childr...

Страница 13: ...IV NOTES FOR USING THE INSTRUMENT...

Страница 14: ...ght indoor lights may affect the results of measurements 4 Do not use organic solutions such as alcohol thinner benzene etc to clean the surface of this instrument These may damage the product 5 Disco...

Страница 15: ...V CONFIGURATIONS...

Страница 16: ...ng the unit ON and OFF 6 Power socket for connecting the power supply 7 Brightness adjustment 8 USB port for remote control for communicating with the remote control and main control box 9 USB port po...

Страница 17: ...VI INSTALLATION...

Страница 18: ...ne the patient while ensuring that the charts are changing properly The product must be set up so that the centre of the LCD screen is level with the patient s eyes ensuring that it is not affected by...

Страница 19: ...VII TEST METHOD...

Страница 20: ...e red circle clearer 0 25D should be added in a left eye until he can see that Red Green circles are just alike But if the green circle was shown clearer 0 25D should be added in a left eye until the...

Страница 21: ...between interval Also asking if a left and a right border are alike or which one is shown smaller than the other The patient s binocular condition is left right and right eye left eye The patient s bi...

Страница 22: ...measuring vertical horizon tal fixation disparity of right or left eye by using polarizing filter 1 Show cross phoria test type to a patient 2 Let a patient wear Red Green glasses right eye red filte...

Страница 23: ...e ideal if the patient could see mark 3 Judge a patient s binocular function as below while asking him how the type is seen Patient s visual status Fixation disparity Method Esophoria Add B O prism un...

Страница 24: ...VIII REMOTE CONTROL FUNCTION...

Страница 25: ...1 GENERAL FUNCTION CSPOLA600 CSPOLA600C Polarized visual chart system V5 03 2018 30 USER MANUAL VIII REMOTE CONTROL FUNCTION...

Страница 26: ...ional function can be selected after slide button press 2 Charts can be changed for quality improvement without notice USER MANUAL VIII REMOTE CONTROL FUNCTION 31 CSPOLA600 CSPOLA600C Polarized visual...

Страница 27: ...IX HOW TO RECHARGE A REMOTE CONTROL...

Страница 28: ...Remote control can be rechargeable by the USB adapter CSPOLA600 CSPOLA600C Polarized visual chart system V5 03 2018 34 USER MANUAL IX HOW TO RECHARGE A REMOTE CONTROL...

Страница 29: ...X UPGRADING A CSPOLA600 CSPOLA600C SYSTEM...

Страница 30: ...the CSPOLA600 CSPOLA600C Auto slide will start after 4 minutes using the images saved in the Slide folder if no key is pressed on the remote control Please check that Engineer mode has been selected b...

Страница 31: ...XI SPECIFICATIONS...

Страница 32: ...6 m 0 25 or 0 5m step adjustment Memory card IDE type Flash Disk Module 4G Power supply 100 240V 50 60Hz 1 5A 1 5A 0 7A Product 12V 5 0A Communication Cable RS 232 Communication Wireless IRDA Communi...

Страница 33: ...XII COMPONENT LIST...

Страница 34: ...Wall mounting bracket Power adapter Power supply ref BPM060S12F25 USB adapter for remote control recharge USB cable for remoter control Power cable User manual CSPOLA600 CSPOLA600C Polarized visual c...

Страница 35: ...XIII SERVICE INFORMATION...

Страница 36: ...nt operates properly with the remote control If the equipment does not operate properly carry out the following steps Check the model name and serial number of the equipment and contact the distributo...

Страница 37: ...Essilor Instruments USA 8600 W Catalpa Avenue Suite 703 Chicago IL 60656 Phone 855 393 4647 Email info essilorinstrumentsusa com www essilorinstrumentsusa com...