PRECAUTIONS

This equipment has been developed and tested in accordance with safety standards as well as national and

international standards. This guarantees a very high degree of safety for this device.
Under legislation currently in force, we are required to inform users expressly about the device's safety

aspects. The correct handling of this equipment is imperative for its safe operation. Therefore, please read all

instructions carefully  before switching on this device. For more detailed information, please contact our

Customer Service Department or one of our authorized representatives.

1. This equipment must not be used:

(a) in areas where there is a risk of explosion and
(b) in the presence of flammable, explosive, or volatile solvents such as alcohol, benzene or similar
chemicals.

2. Do not put or use this device in humid rooms. Humidity should be maintained at between 30 and 75%

for normal operation. Do not expose the device to water splashes, dripping water, or sprayed water.
Do not place containers containing fluids, liquids, or gases on top of any electrical equipment or
devices.

3. The equipment must be operated only by, or under the direct supervision of a properly trained and

qualified person.

4. Modifications to this equipment may only be carried out by the manufacturer's service technicians or

other authorized persons.

5. Customer maintenance of this equipment may only be performed as stated in the user's manual and

service manual. Any additional maintenance may only be performed by the manufacturer's service
technicians or other authorized persons.

6. The manufacturer is only responsible for any effects on safety, reliability, and performance of this

equipment on condition that the following requirements have been fulfilled:
(1) the electrical installation in the respective room is consistent with the specifications stated in this
manual and,
(2) this equipment is used, operated, and maintained according to the instructions given in this
manual and the service manual.

7. The manufacturer is not liable for damage caused by unauthorized tampering with the device(s). Such

tampering will forfeit any rights to claim under warranty.

8. This equipment may only be used together with accessories supplied by the manufacturer. If the

customer makes use of other accessories, they should only be used if it has been demonstrated that
they may be used safely and if this has been confirmed by the manufacturer of the accessory.

9. Only persons who have undergone proper training and instructions are authorized to install, use,

operate, and maintain this equipment.

10.Keep the user's and service manuals in a place that can be accessed any time by the persons

operating and maintaining the equipment.

11.Do not force cable connections. If a cable does not connect easily, be sure that the connector (plug) is

appropriate for the receptacle (socket). If you cause any damage to a cable connector(s) or
receptacle(s), the damage must be repaired by an authorized service technician.

12.Please do not pull on any of the cables. Always hold on to the plug when disconnecting cables.
13.This equipment may be used for the international application.
14.Before every operation, visually check the equipment for exterior mechanical damage and to ensure

that it is operating properly.

15.Do not cover any of ventilation grids or slits.
16.Immediately turn off and unplug any equipment that gives off smoke, sparks, strange noises or

odours.

17.Use only accessories (including power supply) provided by the manufacturer.

U

SER

 

MANUAL

> II. S

AFETY

 

INFORMATION

13

CSPOLA600 / CSPOLA600C - Polarized visual chart system > V5 - 03-2018

Содержание CS pola 600

Страница 1: ...www essilor instruments com User manual...

Страница 2: ...15 IV NOTES FOR USING THE INSTRUMENT 17 V CONFIGURATIONS 19 VI INSTALLATION 21 1 Viewing distance LCD display position 22 VII TEST METHOD 23 VIII REMOTE CONTROL FUNCTION 29 1 General function 30 2 Sli...

Страница 3: ...I INTRODUCTION...

Страница 4: ...right to make changes to its products or product specifications at any time and without prior notice and is not required to update this documentation to reflect such changes 2 OUTLINE OF PRODUCT OVER...

Страница 5: ...CSPOLA600C is a class I medical device type B This device is compliant with marking Expected useful life 7 years Date of first marking 2013 USER MANUAL I INTRODUCTION 7 CSPOLA600 CSPOLA600C Polarized...

Страница 6: ...II SAFETY INFORMATION...

Страница 7: ...ces have been placed appropriately within the text of this manual to highlight safety related information or information requiring special emphasis All users operators and maintainers must be familiar...

Страница 8: ...d in the appropriate user s or service manual Useful information for the user D C current Polarity Indicates the obligation to collect and separate disposal of electrical and electronic equipment at t...

Страница 9: ...ecially metal Don t disassemble the product or open The warranty is void Be careful not to close the fan located on the lateral or back side of the equipment Don t plug the AC power cord into the outl...

Страница 10: ...that the following requirements have been fulfilled 1 the electrical installation in the respective room is consistent with the specifications stated in this manual and 2 this equipment is used operat...

Страница 11: ...III FEATURES...

Страница 12: ...ight dark places Random function Random feature The eye test may be performed with changes to the positions and arrangement of the figures and letters as well as to the Landolt ring Snellen and Childr...

Страница 13: ...IV NOTES FOR USING THE INSTRUMENT...

Страница 14: ...ght indoor lights may affect the results of measurements 4 Do not use organic solutions such as alcohol thinner benzene etc to clean the surface of this instrument These may damage the product 5 Disco...

Страница 15: ...V CONFIGURATIONS...

Страница 16: ...ng the unit ON and OFF 6 Power socket for connecting the power supply 7 Brightness adjustment 8 USB port for remote control for communicating with the remote control and main control box 9 USB port po...

Страница 17: ...VI INSTALLATION...

Страница 18: ...ne the patient while ensuring that the charts are changing properly The product must be set up so that the centre of the LCD screen is level with the patient s eyes ensuring that it is not affected by...

Страница 19: ...VII TEST METHOD...

Страница 20: ...e red circle clearer 0 25D should be added in a left eye until he can see that Red Green circles are just alike But if the green circle was shown clearer 0 25D should be added in a left eye until the...

Страница 21: ...between interval Also asking if a left and a right border are alike or which one is shown smaller than the other The patient s binocular condition is left right and right eye left eye The patient s bi...

Страница 22: ...measuring vertical horizon tal fixation disparity of right or left eye by using polarizing filter 1 Show cross phoria test type to a patient 2 Let a patient wear Red Green glasses right eye red filte...

Страница 23: ...e ideal if the patient could see mark 3 Judge a patient s binocular function as below while asking him how the type is seen Patient s visual status Fixation disparity Method Esophoria Add B O prism un...

Страница 24: ...VIII REMOTE CONTROL FUNCTION...

Страница 25: ...1 GENERAL FUNCTION CSPOLA600 CSPOLA600C Polarized visual chart system V5 03 2018 30 USER MANUAL VIII REMOTE CONTROL FUNCTION...

Страница 26: ...ional function can be selected after slide button press 2 Charts can be changed for quality improvement without notice USER MANUAL VIII REMOTE CONTROL FUNCTION 31 CSPOLA600 CSPOLA600C Polarized visual...

Страница 27: ...IX HOW TO RECHARGE A REMOTE CONTROL...

Страница 28: ...Remote control can be rechargeable by the USB adapter CSPOLA600 CSPOLA600C Polarized visual chart system V5 03 2018 34 USER MANUAL IX HOW TO RECHARGE A REMOTE CONTROL...

Страница 29: ...X UPGRADING A CSPOLA600 CSPOLA600C SYSTEM...

Страница 30: ...the CSPOLA600 CSPOLA600C Auto slide will start after 4 minutes using the images saved in the Slide folder if no key is pressed on the remote control Please check that Engineer mode has been selected b...

Страница 31: ...XI SPECIFICATIONS...

Страница 32: ...6 m 0 25 or 0 5m step adjustment Memory card IDE type Flash Disk Module 4G Power supply 100 240V 50 60Hz 1 5A 1 5A 0 7A Product 12V 5 0A Communication Cable RS 232 Communication Wireless IRDA Communi...

Страница 33: ...XII COMPONENT LIST...

Страница 34: ...Wall mounting bracket Power adapter Power supply ref BPM060S12F25 USB adapter for remote control recharge USB cable for remoter control Power cable User manual CSPOLA600 CSPOLA600C Polarized visual c...

Страница 35: ...XIII SERVICE INFORMATION...

Страница 36: ...nt operates properly with the remote control If the equipment does not operate properly carry out the following steps Check the model name and serial number of the equipment and contact the distributo...

Страница 37: ...Essilor Instruments USA 8600 W Catalpa Avenue Suite 703 Chicago IL 60656 Phone 855 393 4647 Email info essilorinstrumentsusa com www essilorinstrumentsusa com...

Отзывы: