KE-1000 Mark 3 Programming

 (continued) 

 
To Delete a User Code 

1.  Enter the Floor Manager's Code, followed by the User Location of the User Code you want to 

delete (you will hear three rapid beeps). 

Example: 1-3-5-7-9    1-1-1 

2.  Wait five seconds for the 3 reset beeps (Do not enter any digits until you hear 3 reset beeps) 

 

Programming Momentary Access Time        

Default 

Î

 5 seconds 

The 5-second default time has been found optimum for most elevator applications. However for special 
applications that require a different access time, follow the following steps: 
To Program/Change the Momentary Access Time for 

User Code 1 and 2

1.  First determine the length of time you wish to program as the Momentary Access Time for these 

users.  This is the length of time the corresponding call button will remain enabled after a valid 
User Code 1 or User Code 2 has been entered into the system.  

 Note: For direct call registration, you will need to set the Momentary Access time to 1 second.   

 
2.  Locate the Control Module, remove the cover and locate the black “PROGRAM” button switch on 

the daughter board corresponding to the relay for the controlled floor. 

3.  Press the PROGRAM switch once *. (The Keypad will beep rapidly 4 times) 
4.  At the Keypad, enter 1-1-1-7 to open the memory (you will hear three rapid beeps) and enter a 

combination of “1’s” (for every one second increment) and “5’s”  (for every five second increment) 
that equal your desired Momentary Access Time. Each valid key press (a “1” or a “5”) will 
generate a double beep.  (Do not let more than five seconds elapse between entries or the 
system will reset!!!) 

Example: “1-1-1-7    5-5-5-1-1” 

Î

 17 seconds  

5.  After entering your Momentary Access Time, wait five seconds for the 3 reset beeps. 
 

To Program/Change the Momentary Access Time for 

User Code 3,4 and 5

:  

1.  First determine the length of time you wish to program as the Momentary Access Time for these 

users.  This is the length of time the corresponding call button will remain enabled after a valid 
User Code 3, User Code 4 or User Code 5 has been entered into the system. 

 Note: For direct call registration, you will need to set the Momentary Access time to 1 second. 

 
2. Locate the Control Module, remove the cover and locate black “PROGRAM” button switch on the 

daughter board corresponding to the relay for the controlled floor. 

3.  Press the PROGRAM switch once *. (The Keypad will beep rapidly 4 times) 
4.  At the Keypad, enter 1-1-1-5 to open the memory (you will hear three rapid beeps) and enter a 

combination of “1’s” (for every one second increment) and “5’s”  (for every five second increment) 
that equal your desired Momentary Access Time. Each valid key press (a “1” or a “5”) will 
generate a double beep.  (Do not let more than five seconds elapse between entries or the 
system will reset!!!) 

Example: “1-1-1-5    1-1-5” 

Î

 7 seconds  

5.  After entering your Momentary Access Time, wait five seconds for the 3 reset beeps. 
 

 Notes: * Once the PROGRAM switch has been pressed, you have 2 minutes to begin 

programming. You will hear a double beep with each valid key press.  Once you begin entering the 
combination of 1’s and 5’s do not let more than five seconds elapse between entries or the system 
will reset!!! Maximum Momentary Access Time is 

120 seconds

.

 

 