background image

   

RII116-­‐C-­‐201204.docx                                                                                                                                    Copyright©   2020   Essex   Electronics,   Inc.   All   Rights   Reserved   

Hand-­‐E-­‐Wave

   Installation   Instructions,   HEWMO-­‐2,   HEWMO-­‐1,   HEWMO-­‐3   

Application   

Hand-­‐E-­‐Wave   is   a   touchless   microwave   switch   designed   to   provide   a   DPDT   
relay   normally   open   or   normally   closed   output   when   motion   is   detected   
within   the   detection   zone.   The   switch   can   be   configured   to   provide   a   1   to   
30   second   timed   output   or   a   toggle   (on/off)   output.      

Powering   the   Unit   

Hand-­‐E-­‐Wave   is   powered   with   an   un-­‐switched   12   to   24VAC/DC.

   

   Polarity   

need   not   be   followed;   the   switch   will   work,   as   long   a   there   is   a   correct   
voltage   across   the   red   &   black   wires.      This   input   voltage   cannot   be   in   series   
with   any   connected   locking   mechanism,   such   as   magnetic   locks,   etc..   

Operate   the   Sensor   

Move   your   hand   within   the   detection   zone   to   activate   the   sensor.      The   “Hand”   symbol   will   change   from   Blue   to   Green   and   the   
audio   will   beep   (if   audio   is   enabled)   to   indicate   successful   activation   of   the   sensor   and   relay.      

Wiring      

1

)

   PWR:   12   to   24VAC/DC   

(BLACK)   

2)   PWR:   12   to   24VAC/DC      

(RED)

   

3)   Normally   Closed:   NC   Contact   

(GREY)

,   no   manual   

override.   
4)   COM:   Relay   Common   

(Orange)

   

5)   Normally   Open:   NO   Contact   

(BLUE)   

The   above   contacts   are   in   parallel   with   the   manual   override   
function.   

6)   Normally   Closed:   NC   Contact   

(YELLOW)   

7)   COM:   Relay   Common   

(WHITE)   

The   above   contacts   are   in   series   with   the   manual   override   
function.   
8)   Normally   Open:   NO   Contact   

(GREEN)

,   no   manual   override

.

   

Detection   Zone      

Hand-­‐E-­‐Wave’s   detection   zone   may   be   adjusted   from   2”   to   24”   (typical).      Locate   the   

Detection   Zone

   potentiometer   and   rotate   

with   a   small   standard   screwdriver   clockwise   to   increase   the   sensing   field.      Rotate   counter   clockwise   to   decrease   the   sensing   
field.      Use   a   greater   range   setting   for   an   application   where   there   is   little   traffic,   and   precision   is   not   required.      Caution   should   be   
taken   where   the   door   may   move   into   the   beam   when   closing   or   operating,   as   this   may   also   activate   the   sensor.      Use   a   shorter   
read   range   for   an   application   where   a   positive   deliberate   wave   is   used   to   activate.   

Output   Mode      
Timed   Mode

   is   recommended   for   applications   where   a   momentary   or   timed   output   is   desired.   In   Timed   mode,   detection   activates   

the   relay   for   a   set   period   of   time   (0.5   to   30   seconds)   while   there   is   movement   in   front   of   the   sensor.   To   select   timed   mode,   
remove   the   

Output   Mode

   jumper   (or   place   the   jumper   over   ONE   pin).   To

   SET

   the   output   time,   locate   the   

Output   Time   

potentiometer   and   rotate   clockwise   to   increase   the   output   time   (up   to   30   seconds).   Rotate   counter   clockwise   to   decrease   the   
output   time.   To   trigger   an   automatic   door   opener,   set   the   output   time   to   1   second.      Adjust   this   time   so   that   the   door   would   
remain   unlocked   from   activation   to   egress.   

Toggle   Mode

   is   recommended   for   ON/OFF   switch   applications.      In   toggle   mode,   detection   activates   the   relay   and   a   second   

detection   deactivates   the   relay.   To   select   toggle   mode,   place   the   jumper   over   BOTH   pins   of   the   

Output   Mode

.   

Audio   Control   

Hand-­‐E-­‐Wave’s   audio   feedback   occurs   when   motion   is   detected   within   the   detection   zone.   Audio   can   be   enabled   or   disabled.      To   
enable   audio   feedback,   remove   the   

Audio   Control   

jumper   (or   place   the   jumper   over   ONE   pin).   To   disable   audio   feedback,   place   

the   jumper   over   BOTH   pins   of   the   

Audio   Control

.   

Отзывы: