background image

Care@Home™ 

Door/Window Sensor 

User Guide 

ESUGSC007 

Version 2.0 

September 2017 

Содержание CareHome ES700MGLS

Страница 1: ...Care Home Door Window Sensor User Guide ESUGSC007 Version 2 0 September 2017...

Страница 2: ...cation 4 2 3 Setting Up the MGLS 5 2 4 Testing the MGLS 9 3 Operating the MGLS 10 3 1 LED Indications 10 3 2 Notifications 10 3 3 Supervision 10 3 4 Configuring the MGLS 10 4 Replacing the Battery 11...

Страница 3: ...w Sensor User Guide 3 1 Overview The door window sensor MGLS is a magnetic sensor for detecting opening and closing of doors This sensor consists of A transmitter A magnet Figure 1 Care Home Door Wind...

Страница 4: ...ame surface that is clean dry and smooth Within 400 m 1 312 ft of the control panel CP As high as possible yet at a height accessible for occasional maintenance Consistent with the recommendations in...

Страница 5: ...rame of refrigerator door Refrigerator door NOTE Avoid if possible installation on the top of a door or door frame due to the dust accumulation there 2 3 Setting Up the MGLS To set up the MGLS 1 Inser...

Страница 6: ...it a Move the MGLS at least 2 m 6 ft 7 in away from the CP b Press the tamper switch at least three times Figure 3 MGLS Tamper Switch c Insert the battery observing the correct polarity Figure 4 Batte...

Страница 7: ...rom the CP c Press the tamper switch at least three times Refer to paragraph 2a on page 6 d Insert the battery observing the correct polarity Refer to paragraph 2c on page 6 e Ensure that the pairing...

Страница 8: ...4 6 Clean the surfaces of the mounting locations thoroughly Make sure the locations are dry NOTE Refer to Using Screws on page 16 for information about installing the MGLS using screws 7 Peel off the...

Страница 9: ...ape of the magnet 11 Press the magnet into place 2 4 Testing the MGLS Test the MGLS 1 Open the door which has the MGLS The MGLS LED should light up red 2 Close the door where the MGLS is installed The...

Страница 10: ...ure exceeds the configured temperature threshold The MGLS battery charge is low The MGLS tamper switch is disturbed 3 3 Supervision The MGLS is a supervised device The MGLS periodically transmits its...

Страница 11: ...low the battery must be replaced To replace the battery 1 Insert a screwdriver in the release tab opening of the transmitter and press the tab to release the mounting base Figure 8 Release Mounting Ba...

Страница 12: ...r Window Sensor User Guide 4 Insert the new battery observing the correct polarity 5 When the battery is installed the LED lights up red indicating that the device has powered up successfully 6 Return...

Страница 13: ...to end bi directional ESI protocol Advanced radio supervision algorithm Frequency FSK modulation 869 225 MHz 868 3 MHz Europe and China 916 5 MHz North America and Australia 800 MHz Israel RF coverag...

Страница 14: ...tails Physical Dimensions H x W x D Transmitter 98 x 25 x 25 mm 3 86 x 0 98 x 0 98 in Nagnet 46 x 10 x 15 mm 1 81 x 0 39 x 0 57 in Weight Transmitter 45 g incl battery 0 1 lb Magnet 25 g 0 06 lb Color...

Страница 15: ...method consider the following The magnet is only installed using mounting tape Installation with mounting tape is more common Using screws can reinforce the tape based installation Using Mounting Tape...

Страница 16: ...wall anchors for the screws The screws and wall anchors are not provided A standard Philips screwdriver Installing the MGLS with Screws To install the MGLS using screws 1 Using a screwdriver clear th...

Страница 17: ...to you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to p...

Отзывы: