TURN OFF GAS TO APPLIANCE
1.
Place ON/OFF switch in
0
(OFF position). See Fig 5b.
If gas control is accessible turn main valve knob to the
OFF
full clockwise
position.
3.
Replace appliance access cover (if applicable).
BATTERY REPLACEMENT
Handset—When the battery needs changing the low battery indicator will appear on the display. Use a 9 volt
quality Alkaline type. Replacement is recommended every two years.
Receiver—When the batteries need changing frequent bleeps can be heard for three seconds when the motor
turns. The appliance should be cold, remove the receiver box from underneath the appliance and replace the
batteries with 4 x 1.5 volts “AA” type quality Alkaline.
10. COMBUSTION MONITORING SYSTEM
This heater is fitted with a combustion monitoring system device (ODS). If the heater shuts off during use for
no apparent reason then several reasons may be suspected. If a door or window has been opened creating a
draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The
heater can then be re-lit in accordance with the previous section. If pilot disturbance is not the cause, then the
ODS safety system may be in operation. Switch the heater OFF; call in your installer to check the heater and
ventilation. Remedial work must be carried out as required. DO NOT allow the heater to be used until the
heater and installation is passed as safe. If the pilot continues to be extinguished, you must call your installer
to check the operation of the complete heater.
11. CLEANING
Ensure that the heater is turned off before cleaning and is cold. DO NOT use abrasive cleaning agents. Glass
panels can be cleaned with a suitable glass cleaner. Test on a small area first.
12. SERVICING
It is essential that the heater is regularly serviced at least annually.