Esse 700 27B Скачать руководство пользователя страница 2

INSTALLATION & OPERATING INSTRUCTIONS

FOR THE ESSE 700 27B MODEL

U.K. & Ireland

READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE

Contents

Safety Notes

 

                                                                                              Page  3 

                                        

Page  4

                           

Chimney and Flue

         

Page  4

Flue and Draught Measurement                                          

Page  5

  

Flue Diagnosis                                                                  

Page  6

Flue Stabiliser                                                                   

Page  7

Installing the stove                                                                     

Page  7

                                                                   

    Positioning                                                                        

page  7

         Hearth

                   

Page  7

 

   

         Flue connection                                                                 

Page  8 

         Important installation notes

 

Page  8

         Positioning internal components 

                     

Page  8,9,10

         Stove outputs                                                                   

Page  11

         The domestic and central heating system   

         

Page  11

         Final Checks                                                                     

Page  12

 

                  Boiler Tapping                                                                   

Page 12

………………………………………………………………………………………………

                                             

Page  14  

              

 Wood                                                                            

    Page  15

               • Lighting and controlling the fire                                           

Page  15

     • Correct running temperatures for wood burning                    

Page   17

 

     • Extended burning                                                              

Page   17

     • Types of wood for fuel 

        

Page   17

         

Stove Guarantee                                                               

Page  19

2

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS

Содержание 700 27B

Страница 1: ...27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves Cookers Long Ing Barnoldswick Lancashire BB18 6BN United Kingdom Tel 44 0 1282 813235 F 44 0 1282 816876 enquiries esse com www es...

Страница 2: ...itioning page 7 Hearth Page 7 Flue connection Page 8 Important installation notes Page 8 Positioning internal components Page 8 9 10 Stove outputs Page 11 The domestic and central heating system Page...

Страница 3: ...e restricted This appliance requires an air supply of 100 square cm 16 Square Inches in order to provide an adequate amount of air for successful combustion It is important that flue ways are cleaned...

Страница 4: ...y New chimneys must be built in accordance with local building regulations Existing chimneys must be tested in accordance with HETAS requirements If the stove is installed as a free standing appliance...

Страница 5: ...he chimney doesn t pull the smoke it may suggest the chimney needs attention see the Flue Diagnosis Table below Note This test is only a guide as an apparently poor flue may improve once the stove is...

Страница 6: ...aken with the thermostatic air intake closed and the airwash control fully open Maximum The thermostatic air intake can now be opened to allow the stove to burn at maximum rate Give the stove some tim...

Страница 7: ...distances between the stove and surrounding combustible materials As a rule any surrounding combustible material should not exceed 80 C There should be sufficient space around the stove for service wo...

Страница 8: ...ly shows a suitable flue connection Important installation notes 1 The installation must allow for adequate chimney sweeping 2 Avoid using bends greater than 45 to the vertical All pipe flue sections...

Страница 9: ...Perforated sides and back Vermiculite metal side front Vermiculite metal side rear Ashpan Steel plate Cast plate Front Bar Operating Tool Secondary Air Tube Boiler 9...

Страница 10: ...Outputs The maximum Output of the 700 17B Model is 8 0 kW 27 296 Btu h to water and 9 0kW 30 700 Btu h to the room The figures are based upon burning 5 0Kg of wood hour with all controls open and door...

Страница 11: ...r Tappings are 1 diameter BSP and should be connected so the primary flow and return pipes rise continuously to the open vent In order to promote a warm return water temperature a pipe thermostat shou...

Страница 12: ...e should be adjusted to suit the circuit and the whole system balanced properly Boiler Tapping Information 530 150 Ouzledale Foundry Co Ltd Long ing Barnoldswick Lancashire BB18 6BN England Http www e...