Esse 200XK Скачать руководство пользователя страница 23

Page 23 

200-XK-I06-201217 

 

MAINTENANCE 

 
CLEANING THE STOVE 
 
The stove should only be cleaned when it is cold. The exterior can be dusted with a firm 
brush. Do not use a cloth, as this will drag on the paint finish leaving lint on the surface.  
From time to time it may be necessary to renovate the exterior by repainting. High 
temperature stove paints in aerosol form are available from your stove dealer. Do not 
use this form of paint until the stove is cold and always read the instructions on the 
container before starting to paint. The door glass is made

 

of a special heat resisting 

ceramic and may be cleaned when cold with proprietary glass cleaning liquids and a dry 
cloth. 
 
SHUTTING DOWN THE STOVE (LONG TERM) 
 
The following procedure should be followed if the stove is not to be used for a long 
period, summertime for instance. Remove all the ashes from the grate and ash pan and 
use a vacuum cleaner nozzle to clean ash from the base of the stove. Remove the baffle 
plate and brush the flue ways. Close the door and open the air inlets fully. This action 
will allow air circulation through the flue ways and help avoid corrosion and 
condensation. 
 
SERVICING 
 
Regular maintenance should be carried out by a competent engineer. 
 
 
 

GUARANTEE 

 
CONDITIONS OF GUARANTEE 
 
Your ESSE is guaranteed against defects arising from faulty manufacture for 2 years 
when supplied by an ESSE Specialist.  

Upon registration of the warranty, ESSE will extend the guarantee period to 5 years from 
purchase. Your details must be registered with us by either returning the completed 
warranty card or by completing registration on-line at 

www.esse.com

.  The warranty 

must be registered within 1 month of installation to qualify for the 5 year warranty. 
 
The appliance must be only used for normal domestic purposes and in accordance with 
our instructions, be correctly installed and serviced. 

The guarantee does not cover: 
Installation 
Wear and tear 

Содержание 200XK

Страница 1: ...200XK 200XK DD 225XK Multi Fuel Smoke Exempt Wood Burning Stove INSTALLATION USER INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK IRELAND GB IE...

Страница 2: ...ntilate the room Let the fire burn out or eject and safely dispose of fuel from the appliance Once the fire is cold check the flue and chimney for blockages and clean if required Do not attempt to rel...

Страница 3: ...nd In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland...

Страница 4: ...n 320cm 200mm If a flue liner is used it should be 125mm diameter 5 and suitable for solid fuel Be a minimum 4 5m high from hearth level to pot Be terminated at least 1m above roof level so that the c...

Страница 5: ...Page 5 200 XK I06 201217 Fig 1 Ideal Flue Connections Flue box available from www esseparts com Fig 2 Chimney and Flue Performance...

Страница 6: ...should now be taken with the primary air intake closed and the airwash control fully open MAXIMUM The primary air intake can now be opened to allow the stove to burn at maximum rate Give the stove so...

Страница 7: ...reduce the draught through the stove if the flue draught is too high The flue stabiliser should be Fitted in the same room as the stove The same size as the flue pipe Fitted no closer than 700mm to th...

Страница 8: ...Page 8 200 XK I06 201217 Fig 3c 200 Stove with Optional Log Box Dimensions...

Страница 9: ...Page 9 200 XK I06 201217 Fig 3c 225 Stove Dimensions...

Страница 10: ...o Installation Engineer Company Name Address Telephone No Commissioning Checks to be completed and signed Is the flue system correct for this appliance Yes No Flue swept and checked for soundness Yes...

Страница 11: ...olid Fuel Boilers and Packages of Solid Fuel Boilers Supplementary Heaters Temperature Controls and Solar Devices Esse 200SE Note The product fiche can cover a number of solid fuel boiler models suppl...

Страница 12: ...m thick non combustible hearth FLUE CONNECTION The flue pipe used to connect the stove to the chimney is 125mm 5 in diameter The stove is supplied ready for top flue connection To change to a rear con...

Страница 13: ...for Top or Rear Outlet 200 Stove rear flue connection conversion The stove is supplied ready for a top flue connection 1 Unfasten the flue blanking plate 2 Using the same bolts fasten either the optio...

Страница 14: ...ir inlet bracket Fitting the Optional Log Box Remove the stove legs The stove can then be carefully sat on top of the log box The stove can then be bolted to the base using the bolts from the stove le...

Страница 15: ...It is essential that the fire has adequate air supply for combustion and ventilation Apertures provided for this purpose shall not be restricted Additional loose parts supplied inside your stove inclu...

Страница 16: ...Page 16 200 XK I06 201217 Fig 7 Riddling Grate Open Fig 8 Riddling Grate Closed Fig 9 Positioning Vermiculite Bricks...

Страница 17: ...here are too few embers in the fire bed add suitable kindling to prevent excessive smoke FUEL OVERLOADING The maximum amount of fuel specified in this manual should not be exceeded overloading can cau...

Страница 18: ...When reviving a low fire it is important to also use kindling before adding larger logs to help prevent smoke Wood burns most efficiently when the air for combustion is supplied from above the fire be...

Страница 19: ...s coming from the end grain of the wood will dirty the glass TYPES OF WOOD FOR FUEL For best results use well seasoned hardwood such as Oak Ash or Beech Allow wood to dry out under cover in well venti...

Страница 20: ...in order to hit the stove back up to temperature and drive off the moisture and gases in the fuel If a lot of smoke is produced on reloading the air wash control can be opened further to keep the smo...

Страница 21: ...ON Normal heat output wood 7 6kW Nominal heat output solid mineral fuel 7 1kW Weight of stove 99kg Minimum chimney draught 12Pa Mean flue gas temperature wood 229 C Mean flue gas temperature solid min...

Страница 22: ...Page 22 200 XK I06 201217...

Страница 23: ...e grate and ash pan and use a vacuum cleaner nozzle to clean ash from the base of the stove Remove the baffle plate and brush the flue ways Close the door and open the air inlets fully This action wil...

Страница 24: ...rns to our attention We will assess the nature of the complaint and either send replacement parts for your dealer to fit or arrange for an ESSE engineer to inspect the appliance and carry out any work...

Страница 25: ...Monmouth NP25 3LX 01446 771567 info topstak co uk 01600 711710 info topstak co uk Esse Woodburning and Multifuel stoves supplied by Topstak www topstak co uk stoves sto ves by brand esse stoves We ha...