Esprit Tech FALCON-120 Скачать руководство пользователя страница 6

 

G

ALVANIC ISOLATION

 

The FALCON-80 and FALCON-120/130 have an optically isolated throttle input. The FALCON-220 uses galvanic 
separation for all signal cables. 
 

FALCON-80 and FALCON-120/130 schematic: 

 
 
FALCON-220 schematic: 

 

 

 

F

AN CONTROL

 

The FALCON-220 contains a driven output for the external fan (5V, up to 300mA). It is activated as soon as the 

controller temperature reaches 55°C. 

 

 

 

Содержание FALCON-120

Страница 1: ...EN FR IT FALCON 80 FALCON 120 FALCON 130 FALCON 220 Dimensions 57x35x28mm 58x53x24mm 58x53x28mm 81x63x36mm Weight incl cables 60g 110g 110g 270g Continuous current 80A 120A 130A 220A Peak current 120A...

Страница 2: ...configured acceleration time is always applied when accelerating This is a default mode for major use Fast mode the preconfigured acceleration is applied only when spinning up from zero revolutions Af...

Страница 3: ...econditions large outrunner with more than 20 poles heavy propeller large current peaks We also recommend increasing timing to more than 20 High speed use this mode if your power setup exceeds 250 000...

Страница 4: ...er This sensor T125 ID might be used as a standalone telemetry sensor with Duplex Hott S Bus2 telemetry support Alternatively the sensor can be directly connected to the Input port A of the controller...

Страница 5: ...d LED continuously flashes Available status codes Low voltage UL The battery voltage got below the threshold specified in the battery protection menu and the controller either reduced the maximum powe...

Страница 6: ...tle input The FALCON 220 uses galvanic separation for all signal cables FALCON 80 and FALCON 120 130 schematic FALCON 220 schematic FAN CONTROL The FALCON 220 contains a driven output for the external...

Страница 7: ...e compared to the maximum battery voltage from the previous run This means that each time you connect a fully charged battery of the same chemistry and number of cells the capacity will be cleared Man...

Страница 8: ...total energy is limited F5B F5D 9 Temperature C 10 External temperature C if the motor identification chip is connected the ESC forwards motor temperature in its own telemetry 11 Motor status 0 Initi...

Страница 9: ...nnect the Telemetry cable red connector to the Prog SRXL2 receiver port The controller normally delivers only numerical telemetry The textual menu TextGen is available only after a special procedure i...

Страница 10: ...ttery to more than 40cm in total solder some high capacity low ESR capacitors 220 470uF every 30cm in parallel to the power wires Always use high quality connectors in good condition Replace them if a...

Страница 11: ...y port The controller will be automatically detected 4 Select the correct BIN file and press the Update button Note The FALCON 80 and FALCON 120 130 do not require connecting the flight pack prior to...

Страница 12: ...12...

Отзывы: