Exciter Oil Change
The exciter housing is pre-serviced using Automatic Transmission Fluid Dextron III, Mercon, EXXON (ESSO)
NUTO H-32 or its equivalent. Change fluid after 200 hours of operation.
1.
Let exciter cool before changing exciter oil.
2.
Tilt the plate toward a drain pan to aid in the removal of all used oil and particles.
3.
Remove oil drain plug to drain oil from the exciter assembly. Examine oil for metal chips as a
precaution to future problems.
4.
After oil has been completely drained from the machine, reinstall drain plug.
5.
Return plate housing to the upright position.
6.
Add the exciter housing with exciter oil through filler plug opening.
Do not overfill – overfilling can result in excessive temperatures in the exciter.
7.
Apply sealant to filler plug and reinstall it.
Oil Filler Plug
Oil Drain Plug
Содержание XTP9
Страница 2: ......
Страница 20: ......
Страница 38: ......
Страница 56: ...R J YTYSKUVA SPR NGBILD EXPLODED VIEW...
Страница 57: ......