EN
13
8. POSSIBLE FAULTS, CAUSES AND SOLUTIONS
1)
The motor does not start.
2)
Motor operates but there is no pressure.
3)
Motor over-heating.
4)
Pump does not deliver rated capacity.
5)
Motor starts and stops automatically.
6)
Shaft rotates with difficulty.
9. TECHNICAL DATA
Liquid temperature: ......................... 4ºC - 40ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
Ambient relative humidity, max.: ............... 95%
Motor class
I
.
Other data see Figure 3.
1
2
3
4
5
6
POSSIBLE PROBLEM
SOLUTIONS
X
X
Pump blocked
Disconnect it and take it to the official Technical
Service
X
Foot valve clogged
Clean it or replaced by new one
X
X
Total head higher than expected
Verify geometric head and loss of head
X
X
X
Wrong tension
Check that the tension is the same as that on the
name plate
X
X
Water level in well or tank has come
down
Verify suction head
X
Fuse or thermal relay disconnected
Change fuse or thermal relay
X
X
Impellers are worn out
Disconnect pump and take it to your Service
Dealer
X
Foot valve not submerged
Be sure suction pipe is submerged
X
Pump was not primed
Fill pump body with water
X
X
Room not properly aired
Provide good ventilation
X
Air entry
Seal unions and joints properly
Содержание VE121
Страница 2: ......
Страница 34: ...RU 34 5 A B C 3 D 0 03 E F G H I 8 J K L...
Страница 36: ...RU 36 50 2 3 2 30 3 10 1 3 3 4 5 www espa ru 6 7 1 2 3 4 5 P2 6 7 8 9 10 11 12 13 14 15...
Страница 38: ...ZH 38 5 A B C 3mm D 0 03A E F G H I 8 J K L...
Страница 40: ...ZH 40 3 5 4 5 www espa com 6 1 2 3 4 5 P2 6 EC 7 8 9 10 11 12 MEI 13 14 15...
Страница 41: ...ZH 41 7 1 2 3 4 5 6 8 4 C 40 C 0 C 40 C 10 C 50 C 95 I 1 2 3 4 5 6 X X X X X X X X X X X X X X X X X X...
Страница 42: ...AR 42...
Страница 43: ...AR 43...
Страница 44: ...44...
Страница 46: ...46 Fig 3 Abb 3 Afb 3 3 3 3...
Страница 47: ...47 Fig 4 Abb 4 Afb 4 P c 4 4 4 Fig 5 Abb 5 Afb 5 5 5 5...
Страница 48: ...C d 2258 01 2021 09 48...