CAUTION: 

To  prevent  personal  injury,  ensure  all  water 

pressure is released from the pressure system prior to work 
being  performed.  Ensure  pumps  are  disconnected  and  /  or 
electrically isolated.

WARNING:

It  is  strongly  recommended  that  the  system  is 

protected by a suitable pressure relief valve set at or below 
the  maximum  tank  pressure  rating.  Failure  to  install  a  relief 
valve  may  result  in  tank  explosion  in the  event of  a  system 
malfunction  or  over  pressurization,  resulting  in  property 
damage, serious personal injury or death.

WARNING:

If  the  pressure  tank  leaks  or  shows  signs  of 

corrosion or damage do not use it.

Installed on

 __________ 

by

 ________________

W

These instructions have been prepared to acquaint you with the 
correct  method  of  installing and  operating  your GWS  pressure 
tank.  We urge you to study this document carefully and follow all 

the need for further advice, you should contact the dealer from 

PressureWave™,  Max™,  UltraMax™,  M-Inox™,  E-Wave™,  
All-Weather™,  Challenger™,  C2-Lite  CAD™,  and 
FlowThru™ Series tanks are designed for use in well water or 
potable water booster systems. Refer to Sec. 1 for installation 
details.
HeatWave™  and  SolarWave™  Series  tanks  are  designed 
for  use  in  non-potable  closed  loop  hydronic  or  solar  water 
heating systems. Refer to Sec. 2 for installation details.
ThermoWave™ Series tanks are designed for use in open loop 
potable water heating applications. PressureWave™, E-Wave™, 
Challenger™  and  SuperFlow™  Series  may  also  be  used  in 
open loop potable water heating applications. Refer to Sec. 2 
for installation details.
See  tank  data  label  for  maximum  working  pressure  and 
maximum temperature.
Be  sure  to  protect  tank,  piping  and  all  system  components 
from freezing temperatures.
The manufacturer is not responsible for any water damage in 
connection with this diaphragm pressure tank.

Installation

In  order  to  ensure  your  tank  provides  its  maximum  service 
life  it  should  always  be  installed  in  a  covered,  dry  position. The 
tank should not be allowed to rub against any surrounding hard 
surfaces, such as walls etc.

Install  the  tank  at  a  suitable  location  to  prevent  water  damage 
due  to  leaks. The  tank  should  always  be  located  downstream 
from  the  pump.  If  the tank is  located  at  a  lower  elevation  than 
the demand then a check valve should be installed. If the tank is 
installed remotely from the pump then install the pressure switch 
near the tank. The tank should be installed as close as possible to 

adverse effects of added friction loss and differences in elevation 
between  the  tank  and  /  or  the  water  mains’  and  the  pressure 
switch, transducer or sensor.

1.2 System Connection

1.
2. Level  as  necessary.  All  vertical  and  horizontal  model  tanks 

in  the  vicinity  the  tank  should  be  mounted  on  a  resilient 
mounting. Tanks  with  steel  bases  should  be  mounted  using 
supplied “L” brackets, while tanks with plastic bases should be 
mounted  through  the  holes  in  the  base.  For  bases  without 
holes,  holes  should  be  drilled  at  four  points  equally  distant 
along the rim of the base and then mounted accordingly. Inline 
tanks  should  be  connected  directly  to  the  pump  or  to  the 
supply line using a “T” connection.

3. Connect the tank to the pump supply line with a short pipe to 

eliminate unnecessary friction loss.

4. All piping should be in accordance with prevailing local codes 

and standards.

5.

connections.

6. Tanks mounted on booster sets should be strapped down for 

shipment.

1.3 Adjusting Precharge Pressure

Correct precharge is required for proper tank performance.

1. For  tanks  installed  with  a  pressure  switch  controlled  pump 

with  a  differential  pressure  set  up  to  2  bar  (30  psi),  the 
precharge should be set to 0.2 bar (2 psi) below the cut-in 
pressure.

2. For  tanks  installed  with  a  pump  controlled  by  a  pressure 

switch with a pressure differential greater than 2 bar (30 psi), 
electronic controls or variable speed controls, the precharge 
should  be  set  to  65%  of  the  cut-out  or  maximum  system 
pressure.

3. For  tanks  installed  on  mains’  pressure,  the  tank  precharge 

should be set equal to the mains’ pressure. For mains’ pressure 

EN

Содержание C2-Lite CAD series

Страница 1: ...www espa pumps co uk ...

Страница 2: ...ure your tank provides its maximum service life it should always be installed in a covered dry position The tank should not be allowed to rub against any surrounding hard surfaces such as walls etc Install the tank at a suitable location to prevent water damage due to leaks The tank should always be located downstream from the pump If the tank is located at a lower elevation than the demand then a...

Страница 3: ... psi steps and afterwards adjust the system pressure to the new 5 Repeat steps 3 and 4 until the required precharge is reached Emptying a tank that has a precharge over 4 bar 58 psi 1 Make sure there is some water in the tank 2 Isolate the tank from the system close isolation valve 3 Make sure no additional water can get into the tank shut off the pump and or any water supply 4 Release air from ta...

Страница 4: ... to the system when the pump is shut off Fig 1 6 A properly sized tank will store at least one liter of water for every liter per minute LPM of pump capacity This allows for fewer pump starts and longer run times which should maximize the life of the pump 1 Before drawdown 2 During drawdown 3 Pump comes on the tank Fig 1 6 GWS recommends that defective plain steel tanks are replaced with GWS tanks...

Страница 5: ...e supported by system piping and should be connected to the system piping using a T connection See Fig 2 3 1 Optional wall mounting brackets are also available for increased support check with your local GWS dealer for more information Vertical tanks with base are designed to be self supporting and should be connected to the system with additional piping See Fig 2 3 2 2 4 Solar Heating System Conn...

Страница 6: ...expressly in lieu of all other warranties expressed delay in delivery or any loss sustained by the buyer nor will GWS be liable for labor and expenses necessary to remove and reinstall replacement product To obtain service under this warranty the consumer must deliver alleged defective product freight prepaid to an authorized GWS distributor or OEM partner GWS will either issue credit or at its op...

Страница 7: ...ring Déclaration de Conformité Declaración de Conformidad Vastaavuusvakuutus In accordance with EU directive 97 23 EC Pressure Vessels Types MT_ _ ST_ _ HT_ _ PT__ Alexander Staudt Technical Manager Luxembourg July 17 2013 GlobalWater Solutions Ltd St Helier JE1 2TR Jersey The Channel Islands DOC ...

Страница 8: ...s Ltd St Helier JE1 2TR Jersey The Channel Islands Declaration of Conformity Declaração de Conformidade Overensstemmelseserklæring Déclaration de Conformité Declaración de Conformidad Vastaavuusvakuutus In accordance with EU directive 97 23 EC Pressure Vessels Types MUPA MUPN MUFA CUPA CUTA CUFA DOC ...

Страница 9: ... 0 0 0 0 0 0 0 0 0 0 0 0 10 10 100 110 0 0 0 0 0 0 0 0 0 0 0 100 0 110 0 0 0 Maximalsystemdruck Maximální tlak v systému Pression max de fonctionnement Pres do sistema Presiunea maxim de operare a sistemului Presión máx de operación del sistema ...

Страница 10: ...MTMA MTMB MTUA MTUB PTPB MUPA MUPN CUPA MUFA CUFA MTPA MTHT MTHH Size steel SS steel steel steel composite steel composite steel steel steel yes yes yes yes yes yes yes yes yes yes no no tanks also inline tanks inline and models sizes with NPT ...

Страница 11: ...Espa Pumps UK Ltd 15 16 Riverside Avenue West Lawford Manningtree Essex CO11 1UN Tel 01206 391291 Fax 01206 391239 sales espa co uk www espa pumps co uk ...

Отзывы: