In the ACUAPRES models, wait around 10 seconds for priming. If the electronic circuit detects no water the pump stops.
The circuit will make 4 attempts. If the pressure cannot be restored during any of these attempts due to a lack of water,
the circuit will remain in permanent fault until it is reactivated manually (disconnecting and reconnecting the power supply).
1 retry
2 retry
3 retry
4 retry
ACUAPRES is equipped with an anti-blocking safety device. Every 100 hours of inactivity, the pump starts up for
2 seconds automatically to prevent the hydraulics from blocking up.
Maintenance
9.
These submersible pumps do not require maintenance.
During frosty periods, remember to drain the line.
If the pump will be out of service for extended periods, it should be removed from the well and stored in a
dry, well-ventilated location.
Warning: In the event of a breakdown, only an authorized technician may replace the power cable or handle
the pump.
Troubleshooting
10.
The pump does not start.
1.
The pump works but does not produce any flow.
2.
The pump stops automatically.
3.
The flow does not match the supplied curve.
4.
Problems
Causes
Solutions
1
No electricity
Check fuses and other protection devices
2
Drop in the well water level
Check that the pump is completely submerged
3
Voltage error
Check that the voltage is the same as indicated
on the name plate
4
Total manometric head greater than
foreseen
Check geometric height plus head loss
1, 3
Thermal protection activated
Reset the thermal protection or wait for it to cool
2
Discharge line disconnected
Connect this line to the outlet of the pump
3, 4
Insufficient well flow
Install the gate valve on the outlet to reduce the
flow of the pump
4
Water intake filter clogged
Clean intake filter
1, 3
Stop caused by level probes
Wait for the well to recover
2
Check valve installed in the wrong direction
Install the valve in the opposite direction
4
Wear in the hydraulics
Contact an Official Repair Center
1, 4
Capacitor not properly connected
(version II)
See wiring diagram
4
Faulty discharge line
Replace the line with a new one
1
Power cable cut
Check the power cable
Instruction Manual
1’
60
’
On
Off
5’
15’
Содержание ACUAPRES
Страница 6: ...ACUAPRES 30 1 9 G H 3 I D 0 03 J E K F 2 3 ACUARIA07 35 1 4 4 31 ACUAPRES 2 0 0...
Страница 7: ...31 4 1 2 ACUAPRES 20 4M 30 6M 3 5 1 ACUAPRES Kit Pres 3 6 1 fn 30 I n 3 4 5 6...
Страница 8: ...32 7 8 10 AQUAPRES 10 4 1 2 3 4 ACUAPRES 100 2 9 1 60 5 15...
Страница 10: ...41 Fig 1 Fig 2 Fig 3...
Страница 14: ...45 A H max 333 min 111 Q max 333 min 111 E I B F J C G K Fig 9 D H...
Страница 15: ...4...
Страница 16: ...4...
Страница 17: ...63 6 C Mieres s n 17820 BANYOLES GIRONA SPAIN Cod 168233 20 0...