Heated or Cooled air is 

distributed evenly 

How it works 
 
The Thermovec is supplied by hot or cold water from your ASHP.  It draws air in from the room in 
which it is installed, blows that air over a heat exchanger and exhausts the air into that room.  The 
temperature of the room is controlled by the Thermovec and the water flow is controlled by a 
three-way valve.   The air is distributed across the room in a much more efficient manner than a 
traditional radiator. 

Note: if the Thermovec is used for cooling, the condensate drain must be connected. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Unit characteristics: 
 

Whisper Technology 

The use of a cross-flow fan combined with wind-guiding technology make the 
Thermovec quiet as a whisper. 

Slimline 

The Thermovec is only 130mm thick – thinner than traditional radiators of similar 
output saving space. 

Elegant Design 

The rounded and clean outline ensures that the Thermovec will blend into any room. 

Easy to use 

With a simplified control menu, the Thermovec can be controlled via the touch-
screen panel or the remote control. Note: if you are using a high-temperature 
source, the Thermovec should be controlled with the remote control because the 
glass whole unit can achieve a temperature of up to 70

°

C to the touch.   

   

Installation  

 

 
Installation precautions 
 
To ensures that the installation is performed correctly and safely and to conform to the warranty 
conditions the Thermovec must be installed by a suitably qualified technician and in accordance 
with this manual. 
The electrical aspects of the installation must be carried out in accordance with current regulations. 
The Thermovec must be correctly earthed. 
The unit must be installed in a position that allows routine maintenance such as cleaning the filter. 

Ambient air is drawn in 

Return 

Flow 

Содержание VFC2.55G

Страница 1: ...Glass Thermovec Installation and Maintenance Manual...

Страница 2: ...iple of units 3 5 Unit characteristics 4 Installation 4 1 Installation precautions 4 2 Installation note places 4 3 Install note schemes 4 4 Conduit connections 5 Usage 5 1 Function description of wir...

Страница 3: ...correct and also to comply with warranty requirements Likewise in the unlikely event of a repair being necessary it should only be carried out by a qualified technician using genuine spare parts suppl...

Страница 4: ...moved a qualified technician must be engaged to do so Using the Thermovec Do not put fingers or any object into any opening in the Thermovec If your Thermovec emits unusual odours or sounds turn the u...

Страница 5: ...50 5750 7200 9400 Water flow rate m3 h 0 22 0 34 0 49 0 62 0 81 Pressure drop kPa 10 6 12 2 26 2 27 5 28 2 Heating capacity W 1350 2500 3350 4300 5200 Water flow rate m3 h 0 23 0 43 0 58 0 74 0 89 Pre...

Страница 6: ...return temperature of 13 C and 27 C ambient air temperature 4 Noise level is measured in the standard anechoic chamber 17dB A 5 Above data is subject to change without prior notification Working cond...

Страница 7: ...rs of similar output saving space Elegant Design The rounded and clean outline ensures that the Thermovec will blend into any room Easy to use With a simplified control menu the Thermovec can be contr...

Страница 8: ...be installed is strong enough to support the weight You are not going to drill through wires pipes or anything else important when securing the brackets The mounting wall is perfectly flat There is no...

Страница 9: ...vec feet they must be attached before installation as shown in the following two diagrams First lay the unit down carefully to protect both the Thermovec and the surface on which it is placed Line up...

Страница 10: ...The distribution pipework should be designed to reduce resistance and automatic air bleed valve incorporated at key points The flow and return should then be connected to the 3 way valve as shown Ther...

Страница 11: ...r to go up a menu level Down Used to decrease a value or to go down a menu level The Thermovec must be bled before power is applied i e before it is switched on Use a screwdriver to open the bleed val...

Страница 12: ...oggle between modes In Auto Heating or Cooling modes the target temperature will show for 5 secs after the mode is selected The display will then revert to ambient temp In Dehumidifying and Ventilatio...

Страница 13: ...seconds In boost mode press the fan speed button once to revert to the previously set fan speed After 5 secs the changed setting will be saved and the display will revert to the default To Switch on B...

Страница 14: ...ode Use and to select a value from 1 to 11 hours before switch off Press again to set the power on delay time Use and to select a value from 1 to 11 hours before switch on Press again to enter sleep m...

Страница 15: ...simultaneously This will display the coil temperature for 3 secs before the display reverts to the default display This isfor information only and cannot be changed Turning the Air Vent on off To turn...

Страница 16: ...se Remedy P4 Ambient Temperature Sensor Ambient Temperature Sensor failed or open circuit Check or replace sensor P5 Coil Temperature Sensor Coil Temperature Sensor failed or open circuit Check or rep...

Страница 17: ...irs should be undertaken by qualified technicians using genuine spare parts supplied by Earth Save Products Ltd Should a leak develop the unit should be switched off and advice sought from your instal...

Страница 18: ...16 of 16 V1 0 Wiring Details Thermovecs can be connected together and incorporated into a building management system PCB I O Ports...

Отзывы: