Specifications. 
 
Packing List. 
  
 

Thermovec 

Installation 

Template 

Manual 

Screw Cap 

Remote 

 

 

 

X 2 

 

Mounting 

Brackets 

Wall Plugs 

Screws 

Condensate 

Drain Pipe 

Feet 

 

 

 

 

 

 
Parameters 
 

Unit Model

 

Units 

ESP VFC 

2.55G 

ESP VFC 

3.95G 

ESP VFC 

5.75G 

ESP VFC 

7.2G 

ESP VFC 

9.4G 

Heating Capacity①

 

W

 

2550

 

3950

 

5750

 

7200

 

9400

 

Water flow rate①

 

m3/h

 

0.22

 

0.34

 

0.49

 

0.62

 

0.81

 

Pressure drop①

 

kPa

 

10.6

 

12.2

 

26.2

 

27.5

 

28.2

 

Heating capacity②

 

W

 

1350

 

2500

 

3350

 

4300

 

5200

 

Water flow rate②

 

m3/h

 

0.23

 

0.43

 

0.58

 

0.74

 

0.89

 

Pressure drop②

 

kPa

 

10.8

 

13.1

 

27.5

 

27.9

 

28.5

 

Cooling capacity③

 

W

 

1000

 

1900

 

2500

 

3500

 

4350

 

Water flow rate③ 

m3/h

 

0.17

 

0.33

 

0.43

 

0.60

 

0.75

 

Pressure drop③ 

kPa

 

11.1

 

13.3

 

27.7

 

28.3

 

30.6

 

Air volume

 

m3/h

 

160

 

320

 

460

 

580

 

650

 

Noise pressure at max air 
flow

 

dB(A)

 

30

 

32

 

37

 

39

 

41

 

Noise pressure at min air 
flow 

dB(A)

 

24

 

27

 

28

 

28

 

30

 

Power Supply 

V/Hz 

220-240V~/50Hz 

Power Input

 

W

 

15 

20 

23 

25 

32 

Water In/Out tapping size

 

inch

 

3/4 

3/4 

3/4 

3/4 

3/4 

Condensate Drain size

 

mm

 

16

 

16

 

16

 

16

 

16

 

Net Dimensions(L/W/H) 

mm 

See below 

Shipping Dimensions(L/W/H) 

mm

 

See package label

 

Net weight 

kg

 

See nameplate

 

Содержание VFC2.55G

Страница 1: ...Glass Thermovec Installation and Maintenance Manual...

Страница 2: ...iple of units 3 5 Unit characteristics 4 Installation 4 1 Installation precautions 4 2 Installation note places 4 3 Install note schemes 4 4 Conduit connections 5 Usage 5 1 Function description of wir...

Страница 3: ...correct and also to comply with warranty requirements Likewise in the unlikely event of a repair being necessary it should only be carried out by a qualified technician using genuine spare parts suppl...

Страница 4: ...moved a qualified technician must be engaged to do so Using the Thermovec Do not put fingers or any object into any opening in the Thermovec If your Thermovec emits unusual odours or sounds turn the u...

Страница 5: ...50 5750 7200 9400 Water flow rate m3 h 0 22 0 34 0 49 0 62 0 81 Pressure drop kPa 10 6 12 2 26 2 27 5 28 2 Heating capacity W 1350 2500 3350 4300 5200 Water flow rate m3 h 0 23 0 43 0 58 0 74 0 89 Pre...

Страница 6: ...return temperature of 13 C and 27 C ambient air temperature 4 Noise level is measured in the standard anechoic chamber 17dB A 5 Above data is subject to change without prior notification Working cond...

Страница 7: ...rs of similar output saving space Elegant Design The rounded and clean outline ensures that the Thermovec will blend into any room Easy to use With a simplified control menu the Thermovec can be contr...

Страница 8: ...be installed is strong enough to support the weight You are not going to drill through wires pipes or anything else important when securing the brackets The mounting wall is perfectly flat There is no...

Страница 9: ...vec feet they must be attached before installation as shown in the following two diagrams First lay the unit down carefully to protect both the Thermovec and the surface on which it is placed Line up...

Страница 10: ...The distribution pipework should be designed to reduce resistance and automatic air bleed valve incorporated at key points The flow and return should then be connected to the 3 way valve as shown Ther...

Страница 11: ...r to go up a menu level Down Used to decrease a value or to go down a menu level The Thermovec must be bled before power is applied i e before it is switched on Use a screwdriver to open the bleed val...

Страница 12: ...oggle between modes In Auto Heating or Cooling modes the target temperature will show for 5 secs after the mode is selected The display will then revert to ambient temp In Dehumidifying and Ventilatio...

Страница 13: ...seconds In boost mode press the fan speed button once to revert to the previously set fan speed After 5 secs the changed setting will be saved and the display will revert to the default To Switch on B...

Страница 14: ...ode Use and to select a value from 1 to 11 hours before switch off Press again to set the power on delay time Use and to select a value from 1 to 11 hours before switch on Press again to enter sleep m...

Страница 15: ...simultaneously This will display the coil temperature for 3 secs before the display reverts to the default display This isfor information only and cannot be changed Turning the Air Vent on off To turn...

Страница 16: ...se Remedy P4 Ambient Temperature Sensor Ambient Temperature Sensor failed or open circuit Check or replace sensor P5 Coil Temperature Sensor Coil Temperature Sensor failed or open circuit Check or rep...

Страница 17: ...irs should be undertaken by qualified technicians using genuine spare parts supplied by Earth Save Products Ltd Should a leak develop the unit should be switched off and advice sought from your instal...

Страница 18: ...16 of 16 V1 0 Wiring Details Thermovecs can be connected together and incorporated into a building management system PCB I O Ports...