Control  System  Wiring Diagram

 

                                                    

5

 

Y6

Y5

Y4

Y3

Y2

Y1

NN

N

N

N

N

N

L

N

FG GND

10V

SPD

SPD 10V

GND

FG

P+

N-

CT
1

GN
D

5V

SWCLK
SWDAT

R

S

485

X6

X5

X4

X3

X2

X1

RT7

RT6

RT5

RT
4

RT3

RT2

RT1

TX RX

GND

5V

5V

E4A6

0000FF

170623 V2.

0

AC
 O

U

T

DC
 I

N

12V GND

B2

B1

RT8

CT
2

Y7

Y8

Y9

PE

EC
1

EC
2

CN2

CN28

CN3

J1

CN7

CN6

CN5

CN
4

CN1

CN15

CN16

CN17

CN18

CN19

CN20

CN21

CN22

CN
2

3

J4

J5

P1
6

P1

2

P1
3

P1
4

P1
5

P

1

0

P9

P4

P1
1

P

8

P

5

P6

P7

P1
9

P1

P1
7

P1
8

P2

P3

J2

J6

SPD 10V

EXV

2

EXV1

EC
2

CN
1

1

D1

J2

CN
1

4

GND
RST

SA

FAN

Power supply

By
pa
ss

Va
lv

e

on

of
f

EA

FAN

K1

N

M1

Compre

ss

or

N

L

Fo

ur-
w

ay

va

lv

eK

el

ec

tr

on
ic

expan

sio

n

val
ve

temp

12
V

0V

GN
D

4

85A1

4

85B1

GN
D

4

85A2

4

84B2

HG
1

HG
2

RY1

CN1

CN6

RY
2

CN7

RY
3

CN3

CN8

C

N9

O2 IN2 O1 IN1

V4

GND

V3

VCC

GND

VCC

V2

V1
GND

VCC

2

014-11-06

Monito

r b
oa

rd

sw
it

ch

in

g

p

ow

er

 supply

SA temp

compressor discharge temp

OA temp

compressor suction temp

SA side DX coils in-tube temp

EA side DX coils in-tube temp

SA side DX coils inlet air temp

SA side DX coils outlet air temp

EA side DX coils inlet air temp

EA side DX coils

outlet air temp.

Touch screen controller

220V/50HZ

HP

LP

Fire alarm

4

4

1) Wiring should be done by professional people. Power supply 1-1.5mm

²,

other

 

wires

 

0

.

5-0

.

75mm

² 

2) Wires of

 

the

 

controller

 

and monitor

 

board

 

should

 

be

 

shielded twisted pair wires

 

Содержание ECOCENT AIR MVHR-300V

Страница 1: ......

Страница 2: ...Safety Considerations 3 Unit Specifications 4 Dimensioned Drawings 4 Wiring Diagrams 5 Installation Considerations 6 to 8 Controller Introduction 9 to 13 Contents...

Страница 3: ...used with special power supply Don t share the circuit with other equipment The machine should be fastened at the place of flatness and good ventilation and keep proper distance with surrounding Keep...

Страница 4: ...y W 2000 2300 Rated heating capacity W 2500 2800 Rated cooling power W 550 630 Rated cooling current A 2 6 3 0 Rated heating power W 610 685 Rated heating current A 2 9 3 3 Maximum operating power W 7...

Страница 5: ...M1 Compressor N L Four way valveK electronic expansion valvetemp 12V 0V GND 485A1 485B1 GND 485A2 484B2 HG1 HG2 RY1 CN1 CN6 RY2 CN7 RY3 CN3 CN8 CN9 O2 IN2 O1 IN1 V4 GND V3 VCC GND VCC V2 V1 GND VCC 20...

Страница 6: ...e please consult our service team if necessary A Places with mineral oil like cutting machine oil B Places with salty air C Places with corrosive gas such as sulfur D Places with fluctuant power suppl...

Страница 7: ...e drainpipe should be thermal insulated 5 Electric wiring Note 1 The dotted line area wiring connection should be operated by a professional 2 The wiring for connecting monitoring board touch screen w...

Страница 8: ...meter away from the indoor machine otherwise they will interfere the image and make noise The power of the machine should be shut down if it is not used for a long time To protect the machine the pow...

Страница 9: ...ventilator Timer on off after activate the timer on off function a CLOCK displayed on the top left corner When there is system error there will be messages displayed on the top left corner Cooling mod...

Страница 10: ...anced setting data query or maintenance setting Under basic setting page press PM2 5 or CO2 value to set the targeted value these 2 values will influence the SA fan and EA fan speed after setting temp...

Страница 11: ...nter the system time setting and timer on off setting a press system time at the top right corner to set the system time b after setting the timer on and timer off time then to click the to activate t...

Страница 12: ...r life correction value and return difference value also the defrost value Controller Introduction Press filter life to set different filters life alarm Press correction value return difference to che...

Страница 13: ...re is error displayed on the homepage then can enter this page to check the details password is 5555 if the ventilator works fine then no need to enter this page D Maintenance page THIS PAGE IS FOR DE...

Страница 14: ......

Отзывы: