The system power supply can support up to 5 devices 

1

2

3

MASTER=

7

OFF

6

ON

Only one monitor is set as the MASTER:

All other monitors set as SLAVE:

7

ON

SLAVE=

OFF

6

Power supply to be 

with-in 100 meters 

of monitor 

No cable 

or connection 

polarity 

Total cable run

should not exceed 

150 meters between 

door station and monitor

BUS

BUS

BUS

BUS

Address ID 

01

Address ID 

02

BUS

BUS

POWER
SUPPLY

240vAC 

INPUT

The dipswitches are accessable 

on the rear of the door station

Address ID 

02

Address ID 

03

Address ID 

01

Address ID 

04

MASTER

SLAVE

SLAVE

When using multiple 
door stations ensure 
that each unit has a 
seperate Address ID

Refer to instructions supplied when 
using different version of monitor 
for MASTER/ SLAVE configuration

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

   

 

 

 

   

   

System Connections Example 2

APKITKP Manual.qxp_Layout 1  28/01/2016  11:45  Page 6

Содержание aperta APKIT

Страница 1: ...U S E R M A N U A L w w w e s p u k c o m A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M APKITKP Manual qxp_Layout 1 28 01 2016 11 45 Page 1...

Страница 2: ...ine elandcables com Cables Accessories LAN Cable Cat 5E UTP PVC Cable Contents System Components 3 Installation 4 System Connections Example 1 5 System Connections Example 2 6 Lock Connections Example...

Страница 3: ...NW Monitor APPOWSW System Power Supply EVBPSBB Lock Power Supply EV EXIT Push To Release EV EBG Emergency Release EV ML 250 500XT Electro magnetic Lock ENTERD Electric Lock Optional Accessories APKITK...

Страница 4: ...camera needs to point in the direction of where a visitor will stand during operation Site the indoor monitor to suit application Monitor 1 Gang Mount Box if required not supplied Surface mount the b...

Страница 5: ...ly to be with in 100 meters of monitor No cable or connection polarity Ensure the Address ID switches are both set to OFF Address ID 01 Total cable run should not exceed 150 meters between door statio...

Страница 6: ...r station and monitor BUS BUS BUS BUS Address ID 01 Address ID 02 BUS BUS POWER SUPPLY 240vAC INPUT The dipswitches are accessable on the rear of the door station Address ID 02 Address ID 03 Address I...

Страница 7: ...1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 1 2 3 J1 J2 J3 Image of jumper link The jumpers on the rear of the door station offer different types of release modes for a...

Страница 8: ...Default 123456 2 tones will sound 2 tones will sound Press Setting a lock release code The Administrator code will not release the door A lock release code is required to be programmed Administration...

Страница 9: ...Press Changing the Administrator code Enter code Location Number A long tone will sound Press Press Press Press to exit and complete setup Press to exit and complete setup A long tone will sound Press...

Страница 10: ...a Adjustment for the intensity of colour Talking Volume Adjust the volume level of the monitor Press the Talk button to end call Press the Lock button to release lock and press Talk to end call Press...

Страница 11: ...ench test the system if the issue cannot be found A The user instructions and operation of the monitor has been understood B That the lock is powered sufficiently C All system cabling is secured and p...

Страница 12: ...curity Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 51 51 50 Fax 01527 51 51 43 email info espuk com E OE Errors and omissions excepted A16 APKITKP Manual qxp_Layo...

Отзывы: