21
7.
OTHER SETTING
7.1
DISPLAY MENU [DISP]
7.1.1
Decimal Point
In the value that appears on the display in run mode, you can set the position of the decimal
point in this menu. This value, which is '2' in the factory settings, indicates how many digits
are displayed after the currancy. If you select '0', only the integer appears on the screen.
7.1.2
The Tare Function
In this menu you can specify different Tare functions.
From the EVENT menu you can select the Tare Function type:
Each time the UP button is pressed while the unit is in operation mode, the function of the
selected Tare function is:
7.1.2.1
Tare Input
If your EPA 100, which is manufactured specifically for your order, has the Digital Tare Input
module, you can make settings from the INPUT menu under the Tare menu.
The EDGE option determines which edge of the edge signal coming from the mode will
activate the edge function. RISE for rising edge, FALL for falling edge. For example; When you
connect this signal to a button, the RISE option activates the Tare when the button is pressed
and the FALL option when the button is released. In the FILTR option, you can specify the
number of milliseconds after which the modulated signal is to be checked. By default, this
value is 100 ms.
ZERO: Then the value read on the sensor is
equal to zero and the
T
status led lights.
PRESET: Then the value read on the sensor is equal
to the set value and the
T
status led lights.
REPEATED ZERO: The first time it is pressed, the value read at the
sensor is equal to zero and the
T
status led lights. When it is
pressed later, the read value returns to the state before the key is
activated, and the
T
status led goes out.
REPEATED PRESET: The first time it is pressed, the value read on
the sensor is equalized and the
T
status led lights. When it is
pressed later, the read value returns to the state before the key
is activated, and the
T
status led goes out.
Tare function is completely disabled.
.
.