Carbon dioxide (CO2) detectors 

for homes, recreational vehicles, workplaces and 
more in general, in public or private places with a 
high concentration of people. 

ESN.F.D.. 

 

__________________________________________________________________________________________ 

Electronic microprocessor Carbon Dioxide (CO

2

) detectors

 

Display of carbon dioxide measurement in addition to ambient temperature, relative humidity and the 
operational status of the detector, on large LCD screen

 

NDIR (nondispersive infrared) carbon dioxide detection technology ABC Logic™ self-calibration system 
(automatic calibration)

 

Measuring range 0…20,000 ppm of CO2 (other ranges on request)

 

Power supply 230Vac, 115Vac, 24Vac/dc (see models)

 

Relay command output with potential-free contact (SPST 230Vac / 3A, or 30Vdc / 3A), suitable for any 
command or alarm device.

 

Optional measurement outputs 4…20mA or 0…10Vdc (see models)

 

__________________________________________________________________________________________ 

Use

 

The ESN.F.D.. detectors can be used to measure the concentration of Carbon Dioxide and 
to command transmitters or actuating devices where there are abnormal concentrations well 
below the gas hazard threshold.

 

The ESN.F.D.. detectors can also be used to monitor Carbon Dioxide as an indication of the 
quality of the air in hotels, offices, exhibition centres, shops, restaurants, schools, conference 
rooms, cinemas, theatres and ventilation systems in general.

 

__________________________________________________________________________________________ 

Operation

 

At the end of the warm-up phase, during which the detector is inactive, it enters normal 
operation mode, and will continue in this state until it detects gas.

 

When the gas 

concentration exceeds the threshold set-points, the detector senses its presence and goes 
into the alarm condition indicated by the activation of the relay and by the relative display 
symbol coming on.

 

250...…350 ppm

 

level of the air in outdoor environment (normal)

 

350...…1000 ppm

 

typical level found in living spaces with good air circulation

 

1000…...2000 ppm

  level associated with drowsiness and lack of air

 

2000…...5000 ppm 

level associated with headache, drowsiness and stale, stagnant air like 
a closed room. This could cause lack of concentration, loss of atten-
tion, increased heartbeat and slight nausea

 

> 5000 ppm

 

exposure could lead to a serious lack of oxygen resulting in brain da-
mage, coma and death.

 

__________________________________________________________________________________________ 

Power supply

Outputs 

230Vac

 

115Vac

 

24Vac/dc

 

SPST relay 

ESN.F.D.A.R ESN.F.D.D.R ESN.F.D.E.R 

SPST relay + 4...20mA 

ESN.F.D.A.I ESN.F.D.D.I ESN.F.D.E.I 

SPST relay + 0...10Vdc 

ESN.F.D.A.V ESN.F.D.D.V ESN.F.D.E.V 

For special versions, please contact Customer Service. 

__________________________________________________________________________________________ 

Levels of CO

2

 

and effects on 
humans

 

Available 
models  
and ordering 
information

 