9
ASSEMBLY
ALL-FLEX
™
3 LEG ELECTRIC TABLE BASE
STEP 15
“Zero set” the system before testing operation. (Note that with the table and keypad will be upside-down,
the UP
▲
and DOWN
▼
buttons face their opposite directions.)
• Press and hold the UP
▲
and DOWN
▼
buttons at
the same time. Continue to hold the buttons. The
legs will retract until they reach their bottom point.
• Release the buttons once the system beeps. If it
does not beep, continue to hold the buttons for
3 seconds after the legs reach the lowest point. The
system is now “zero set.”
• Press the UP
▲
or DOWN
▼
buttons to test operation. End your test with the legs lowered and unplug the
power cord.
• If there are problems with operation, check that all cable and cord connections are secure. If problems
continue, call ESI Customer Service.
STEP 16
Use the pre-installed cable clips plus the additional clips provided, to secure the cables in position.
• Cables must not interfere with table operation.
• Cables must not interfere with the user.
Digital Keypad
Work Surface
Press and Hold Both Buttons
Pre-Installed
Cable Clip
Cable Clip