F

irmware Upgrade 

The latest device software 
(firmware) can also be found in 
the download area of the 
ESERA Online Shop.  
The update is performed using 
Config-Tool 3.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

13 

 Operating conditions 

The module may only be operated at the voltages and ambient conditions specified for it. The device can be 
operated in any position. The device is intended for use in dry and dust-free rooms.  
If condensation forms, wait at least 2 hours for the device to acclimatise. 
The modules may only be put into operation under the supervision of a qualified electrician. Do not operate the 
module in an environment where flammable gases, vapours or dust are present or can be present. 
 

14 

Assembly 

The installation site must be protected against moisture. The device may only be used in dry 
indoor rooms. The device is intended for mounting inside a control cabinet as a stationary 
device.  
 

15 

Disposal note  

Do not dispose of the device in household waste! Electronic devices must be disposed of in 
accordance with the Directive on Waste Electrical and Electronic Equipment on local 
Dispose of at collection points for old electronic equipment! 
 

16 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially 
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for 
a part or assembly are, how to connect an external circuit, which external components or additional devices can be 
connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

Содержание 11325

Страница 1: ...to worry about 1 Wire commands or formulas for evaluating sensor data The controller independently scans the 1 Wire network for devices sensors and actuators and depending on the device found outputs the corresponding data in plain text Formatted data output The 1 Wire Controller 1 provides the sensor and actuator data ready prepared e g for temperature sensors in C cyclically off Only one divisio...

Страница 2: ...F EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS 6 Software In order to protect controller 1 from unauthorized access a password key must be entered before a data connection is established This signals to Controller 1 that the connection setup is an authorized access The factory default is key 1304 7 Setting up Bluetooth A Bluetoot...

Страница 3: ...e Controller 1 RFCOMM channel for the connection channel 1 Description of the connection comment 1 Wire_Controller1 Device must of course be adapted rfcomm connect 00 12 6F 2B B1 52 execute in the console Now the serial interface can be accessed with a normal terminal program dev rfcomm0 8 Display LED The module has various display LEDs In the following the function of the displays Display Bezeich...

Страница 4: ... ESERA GmbH ESERA Automation 2020 www esera de 11325 V2 0 R1 0 Manual Page 4 of 8 9 Connection diagram Module top side 1 Wire Bus Module top side 7 ground 1 Wire 8 1 Wire Data 9 5V output Module bottom side power supply 1 Minus Supply voltage 2 Plus Supply voltage Note Basics and tips for the 1 Wire Bus system can be found in our eBook in the shop at http www esera de schulung support dokumentatio...

Страница 5: ...es the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11325 V2 0 R1 0 Manual Page 5 of 8 10 Connection example 1 Wire Hub III sensors and actuators Der 1 Wire Controller 1 Ethernet is shown here as an example of the 1 Wire Controller 1 Bluetooth ...

Страница 6: ...Tool 3 in the form of a COM interface You can find this program in the download area of the ESERA Online shop Configuration and Communication with 1 Wire Controller 1 The 1 Wire Controller 1 has extensive configuration and formatting options that can be read and operated with the ESERA Config Tool 3 Since communication between the 1 Wire controller 1 and the Config tool 3 takes place via the open ...

Страница 7: ...id VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they...

Страница 8: ...ample for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If defects occur f...

Отзывы: