Technical Data
4. Technical Data
4.1 General Technical Data
Connectors
P1
J2
(3-pin PHOENIX CONTACT MINI COMBICON connector)
input voltage (24 V)
(15-pin male multipoint connector, DIN 41 612, construction H) output
voltages (3.3 V and 5 V)
Temperature
range
0...50 °C ambient temperature
Humidity
max. 90%, non-condensing
CPCI dimensions
3 U, 4 HP
PCB dimensions
100 mm x 160 mm
Front panel
CompactPCI conform
Weight
269 g
Table 2:
General data of the module
4.2 24 V-Input
Operating input voltage
range
18 V … 34 V
Electrical isolation
The input is electrically isolated from functional earth (FE) and output.
Electrical grounding
The input shield line should be externally connected to FE to meet the
EMC requirements. The input shield line is connected to the front
panel of the board.
Power consumption
max. 120 W
Input Connector
Connector:
PHOENIX CONTACT MINI COMBICON,
order number: 1803581
Tightening torque:
Min. 0.22 Nm / max. 0.25 Nm
Screw thread:
M2
Required conductor
cross section:
1.5 mm² (*1)
Required AWG
according to
UL/CUL:
14 (*1)
(*1) These values are required for 8 A input current and external 8 A current limitation. Smaller diameter are possible if lower current is sufficient
and the current is limited by an external device.
Table 3:
Input data and input connector
Page 10 of 16
Hardware Manual • Doc. No.: I.2301.21 / Rev. 1.0
CPCI-PS24