![ESD CAN-PC104/331 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/esd/can-pc104-331/can-pc104-331_hardware-installation-and-technical-data_2426434015.webp)
Technical Data
3. Technical Data
3.1 General Technical Data
Ambient
temperature
0...50°C
Humidity
90 %, non-condensing
Power Supply
via PC/104-bus,
nominal voltage: 5 V ±5%,
current (typ. at 20°C):
for 1x CAN:
0.55 A
for 2x CAN:
0.70 A
Connectors
X100 (64-pole PC/104 PCB connector) - PC/104 bus
X101 (40-pole PC/104 PCB connector) - PC/104 bus
X400 (DSUB9/male) - CAN interface 1 (net 0) (C.2012.02, C.2012.04)
X401 (DSUB9/male) - optional CAN interface 2 (net 1) (C.2012.04 only)
X400 (MicroMatch socket) - CAN interface 1 (net 0) (C.2012.09 only)
X401 (MicroMatch socket) - CAN interface 2 (net 1) (C.2012.09 only)
The following connectors are only equipped for programming and service:
X200 (4-pole female con.
- CPU interface (serial, TTL)
X201 (10-pole male connector) - BDM interface
X501 (5-pole male con.)
- ISP programming
Dimensions
95.9 mm x 90.2 mm
Weight
1x CAN: 85 g
2x CAN: 95 g
Table 2:
General technical data
3.2 PC/104 Bus
Host bus
PC/104
PC/104-data bus
16 bit
Interface
IN/OUT-FIFOs (512 bytes each)
Interrupt
1 out of 12
Stack position
no restrictions in position in stack
Connectors
PC/104 PCB connectors, 40-pole and 64-pole
Table 3:
PC/104 bus data
CAN-PC104/331
Hardware Manual • Doc. No.: C.2012.21 / Rev. 1.6
Page 15 of 32