DSUB Adapter and Adapter Cable
CAN-M.2/402-2-FD
Hardware Manual Doc.-Nr.: C.2074.21/ 1.0
Page 13 of 32
4 DSUB Adapter and Adapter Cable
Figure 3:
Adapter CAN-PCIeMini-402-DSUB9
With the adapter CAN-PCIeMini-402-DSUB9 you can connect the CAN interfaces of the CAN-
M.2/402-2-FD via DSUB9 connectors.
The adapter CAN-PCIeMini-CAN/402-DSUB9 is not contained in the scope of delivery of
the CAN-M.2/402-2-FD. S
ee “Order Information” on page 31
The adapter cable
CAN-PCIeMini/402-Cable and two UNC 4-40 DSUB bolts are included in the
scope of delivery of CAN-PCIeMini/402-DSUB. The bolts are intended to be used with a front
panel!
NOTICE
Read chapter “Hardware Installation” on page 15, before you start with the installation of
the CAN-M.2/402-2-FD!
DSUB9
Cable
connector
with cable
Jumper
Figure 4:
Top layer with DSUB9 connector
Figure 5:
Bottom layer with jumper and cable
connector
With the jumper the CAN termination of the connected CAN interface can be set internally.
The jumper is located on the bottom layer of the adapter (see
JumperJP400
Jumper set
Internal termination (120
Ω) of the connected CAN net (CAN0 or CAN1)
Jumper not set
The connected CAN interface has to be terminated externally.
Table 2:
Jumper
4.1 Adapter View
4.2 CAN Termination Jumper