ESD SYSTEMS 41290 Скачать руководство пользователя страница 6

PS-2111

Page 6 of 7

© 2007 DESCO INDUSTRIES INC.

Employee Owned

NORMALIZATION OF SURFACE
RESISTANCE TESTER

Temperature inside testing area needs to
be 75°F @ ±6.6% 40% to 60% RH.
Testers need to stay at constant
temperature 75°F @ ±6.6% for about 2
hours for proper reading. Testers cannot
be inside objects, enclosed boxes,
containers or cases unit is supplied with
(temperature inside case will differ from
outside temperature, cases will act like
an insulator to the Testers), Testers will
have to be stationary in testing area for
about 2 hours with no dramatic
temperature changes.

TESTING OF SURFACE
RESISTANCE TESTER

• When testing use only the leads

supplied with the tester. DO NOT
TEST WITH RESISITIVITY
ATTACHMENT, Resitivity
Attachment will give a much higher
reading and is only designed for spot
checking.

• With 10V/AUTO switch down, press

TEST button - voltage between the
two leads should be 10V ±5%

• With 10V/AUTO switch up, press

TEST button - voltage between the
two leads should be 100V ±5%

• Using the cleaning wipes and 99%

isopropyl, clean around banana jack
and mono jack where leads connects
to, oil from human fingers can alter
accuracy.

• Make sure 10V/AUTO switch is set

to AUTO (switch up). Testing each
decade starting from 1.0 x 10E12 and
down, never start from 1.0 x 10E3.

Temperature 
Fahrenheit

= 75°F ±6.6%

Celsius

= 23.8°C ±10.2%

Relativity Humidity ±10 Digits

A. 1.0 x 10E12

+ 20% LED = 12 Yellow

Mantissa 1.20

0%

LED = 12 Yellow
Mantissa 1.00

- 20%  LED = 11 Yellow

Mantissa 8.00

B. 1.0 x 10E11

+20%

LED = 11 Yellow
Mantissa 1.20

0%

LED = 11 Yellow
Mantissa 1.00

-20%

LED = 10 Green
Mantissa 8.00

C. 1.0 x 10E10

+10%

LED = 10 Green
Mantissa 1.10

0%

LED = 10 Green
Mantissa 1.00

-10%

LED =   9 Green
Mantissa 9.00

D. 1.0 x 10E9

+10%

LED =   9 Green
Mantissa 1.10

0%

LED =   9 Green
Mantissa 1.00

-10%

LED =   8 Blue
Mantissa 9.00

E. 1.0 x 10E8

+10%

LED =   8 Blue
Mantissa 1.10

0%

LED =   8 Blue
Mantissa 1.00

-10%

LED =   7 Blue
Mantissa 9.00

F. 1.0 x 10E7

+10%

LED =   7 Blue
Mantissa 1.10

0%

LED =   7 Blue
Mantissa 1.00

-10%

LED =   6 Blue
Mantissa 9.00

G. 1.0 x 10E6

+10%

LED =   6 Blue
Mantissa 1.10

0%

LED =   6 Blue
Mantissa 1.00

-10%

LED =   5 Green
Mantissa 9.00

H. 1.0 x 10E5

+10%

LED =   5 Green
Mantissa 1.10

0%

LED =   5 Green
Mantissa 1.00

-10%

LED =   4 Green
Mantissa 9.00

I. 1.0 x 10E4

+10%

LED =   4 Green
Mantissa 1.10

0%

LED =   4 Green
Mantissa 1.00

-10%

LED =   3 Red
Mantissa 9.00

J. 1.0 x 10E3

+10%

LED =   3 Red
Mantissa 1.10

0%

LED =   3 Red
Mantissa 1.00

-10%

LED =   <3 Red
Mantissa <0.90

Specifications

Ranges:

1 x 10E3 - 1 x 10E12 ohms @

10 Volts, complies with ANSI/ESD S4.1

1 x 10E6 - 1 x 10E12 ohms @ 100
Volts, complies with ANSI/ESD S4.1

Power Supply:

Two AA alkaline

batteries

Содержание 41290

Страница 1: ...loor Footwear ESD STM97 1 Floor Materials and Footwear Resistance Measurement in Combination with a Person Workstations ESD ADV53 1 ESD Protective Workstations Versatility Measures RTT RTG or Resistivity requires optional Resistivity Attachment item 41292 Quick Checks Surface resistance exponent number illuminates immediately i e 8 10E8 ohms or 100 000 000 ohms Periodic Checks of Installed Product...

Страница 2: ...ing displayed is identified by the illuminated function LED The surface resistance exponent or power of number is immediately illuminated and remains illuminated measuring the range the surface resistance in ohms Reference Literature In addition to those noted above ANSI ESD S20 20 Development of ESD Control Program ESD ADV1 0 Glossary of Terms ANSI ESD S6 1 Grounding These documents can be obtain...

Страница 3: ...urfaces use ESD Systems com Reztore Antistatic Surface and Mat Cleaner item 10630 or other ESD cleaner not containing silicone Be sure the surface is dry before testing Periodic maintenance The area surrounding the cable jacks at the top end of the meter should be wiped with a clean cloth moistened with alcohol to remove skin oils that will accumulate and affect the accuracy at high resistances Th...

Страница 4: ...ulative silicone i e Reztore Antistatic Surface and Mat Cleaner Reporting and Using Test Results Different standards have different requirements use requirements as specified in user s ESD control plan Examples are Per ESD 4 1 worksurfaces Report RTG maximum and minimum values measured for resistance to ground RTT maximum and minimum values measured for point to point resistance in ohms Per ESD 7 ...

Страница 5: ...ing Diodes LED s illuminate exponent numbers and function being performed Accuracy Resistance measurements within 10 E12 and greater 20 complies with ESD S4 1 Open circuit voltages of 10 volts 5 and 100 volts 5 exceeds requirements of ESD S4 1 Meter Weight 15 5 oz Dimensions 8 L x 4 3 W x 1 6 H Test Switch Press the red test button for 15 20 second electrification period Meter will immediately dis...

Страница 6: ...o AUTO switch up Testing each decade starting from 1 0 x 10E12 and down never start from 1 0 x 10E3 Temperature Fahrenheit 75 F 6 6 Celsius 23 8 C 10 2 Relativity Humidity 10 Digits A 1 0 x 10E12 20 LED 12 Yellow Mantissa 1 20 0 LED 12 Yellow Mantissa 1 00 20 LED 11 Yellow Mantissa 8 00 B 1 0 x 10E11 20 LED 11 Yellow Mantissa 1 20 0 LED 11 Yellow Mantissa 1 00 20 LED 10 Green Mantissa 8 00 C 1 0 x...

Страница 7: ...390 for a Return Material Authorization RMA and proper shipping instructions and address Desco will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The expr...

Отзывы: