Technical Data
Installation and technical data
CAN-PCI/360
Rev. 1.3
9
3.4 CAN-Interfaces
In standard option the CAN-PCI/360 is available with four CAN-interfaces in accordance with
ISO11898. The interfaces are accessible via DSUB-connectors. Alternatively, CAN-interfaces 0 and
1 are also available as DeviceNet interfaces. Each CAN- or DeviceNet interface is electrically insulated
from the other units and has got a separate CAN-controller (SJA1000).
3.5 Serial Interfaces
An RS-232 interface is available for the communication withe the microcontroller 68360 (fourth
interface of the 68360). It is connected via a 10-pin post connector.
Optionally the interface is also available with other physical interfaces (RS-422, RS-485 or TTY). This
option has to be specified when the CAN-PCI/360 module is ordered, because it cannot be added later.
The microcontroller ports for serial interfaces 1 to 3 are accessible via a 30-pin SMD-socket strip (type:
SAMTEC CLT-115-02-F-D-A). The socket strip has been designed for the mounting of an add-on
board. Three drilled holes are available to secure such an add-on board.
3.6 The Multiplex Bus
In order to leave the option to access the local bus externally for coming tests or applications, the CAN-
PCI/360 module has got a so-called multiplex bus. It offers a 16-bit wide path to the data bus, 24
address lines, 5 interrupt lines and all control lines required to access a bus multiplexed on 34 connector
pins (X900).