ets-lindgren.com
Specifications
39
Environmental
Operating Temperature:
10
°
C to 40
°
C
50
°
F to 104
°
F
Humidity:
5% to 95% relative humidity,
non-condensing
Dimensions
Probe Length:
438 mm (17.24 in)
(includes electronics housing)
Probe Diameter:
57 mm (2.24 in)
Weight:
0.36 kg (12.64 oz)
Battery-Operated Probe Specifications
HI-6023
S
PECIFICATIONS
Dynamic Range:
2.0
–800 Volts per meter (V/m)
Ranges:
Single
Typical Frequency Response:
10 kHz
–1 GHz
10 kHz
–30 kHz: +0.5 dB, -2.5 dB
30 kHz
–1 GHz: ±1 dB
Typical Frequency Response
with Correction:
10 kHz
–1 GHz: ±0.9 dB
Linearity:
±0.5 dB
Isotropicity:
±0.5 dB @ 400 MHz
Overload Withstand:
> 1,500 V/m CW
Содержание ETS-Lindgren HI-6006
Страница 1: ...HI 6122 HI 6105 HI 6153 HI 6023 HI 6006 HI 6053 EMC Field Probes User Manual ...
Страница 10: ...x ets lindgren com This page intentionally left blank ...
Страница 20: ...20 Typical Configurations ets lindgren com This page intentionally left blank ...
Страница 34: ...34 Maintenance ets lindgren com This page intentionally left blank ...
Страница 44: ...44 Specifications ets lindgren com This page intentionally left blank ...
Страница 61: ...ets lindgren com Typical Data Laser Powered Probes 61 Typical Isotropic Response in dB at 10 GHz ...
Страница 62: ...62 Typical Data Laser Powered Probes ets lindgren com Typical Isotropic Response in dB at 18 GHz ...
Страница 69: ...ets lindgren com Typical Data Battery Operated Probes 69 Typical Isotropic Response in dB at 10 GHz ...
Страница 70: ...70 Typical Data Battery Operated Probes ets lindgren com Typical Isotropic Response in dB at 18 GHz ...
Страница 72: ...72 Warranty ets lindgren com This page intentionally left blank ...
Страница 138: ...138 ETSProbe DLL User Guide ets lindgren com This page intentionally left blank ...