User Manual Rev. 1.8

 

5

 

 

 Use a double-walled carton of sufficient strength for the weight being shipped 

 Use heavy paper or cardboard to protect all instrument surfaces. Use non-abrasive 

material around all projecting parts  

 Use  at  least  four  inches  of  tightly  packed,  industrial-approved,  shock-absorbent 

material all around the instrument 

 
Esco Medical will not be held responsible for lost shipments or instruments received 
in  damaged  condition  due  to  improper  packaging  or  handling.  All  warranty  claim 
shipments must be made on a prepaid basis (freight, duty, brokerage, and taxes). No 
returns  will  be  accepted  without  a  Return  Materials  Authorization 

("RMA”)  number. 

Please  contact  Esco  Medical  to  obtain  an  RMA  number  and  receive  help  with 
shipping/customs documentation. 
 
Recalibration of instruments, which to be calibrated according to the recommended 
annual calibration frequency, is not covered by the warranty. 

 
Warranty Disclaimer 

Should you choose to have your instrument serviced and/or calibrated by someone 

other  than  Esco  Medical  Ltd.  and  their  representatives,  please  be  advised  that  the 
original  warranty  covering  your  product  becomes  void  when  the  tamper-resistant 
Quality Seal is removed or broken without proper factory authorization. 

 
In  all  cases,  breaking  the  tamper-resistant  Quality  Seal  should  be  avoided  at  all 

costs, as this seal is key to your original instrument warranty. In an event where the 
seal must be broken to gain internal access to the instrument, you must first contact 
Esco Medical Ltd. 
 
You will be required to provide us with the serial number for your instrument, as well 
as a valid reason for breaking the Quality Seal. You should break this seal only after 
you receive factory authorization. Do not break the Quality Seal until you have con-
tacted us! Following these steps will help ensure that you will retain the original war-
ranty on your instrument without interruption.  

 
WARNING 

Unauthorized  user  modifications  or  application  beyond  the  published  specifications 
may result in electrical shock hazard or improper operation. Esco Medical will not be 
held  responsible  for  any  injury  sustained  due  to  unauthorized  equipment  modifica-
tions.  
 
ESCO  MEDICAL  LTD.  DISCLAIMS  ALL  OTHER WARRANTIES,  EXPRESSED  OR 
IMPLIED,  INCLUDING  ANY  WARRANTY  OF  MERCHANTABILITY  OR  FITNESS 
FOR A PARTICULAR PURPOSE OR APPLICATION. 
THIS 

PRODUCT 

DOES 

NOT 

CONTAIN 

ANY 

USER-SERVICEABLE 

Содержание AVT-1

Страница 1: ...Rev 1 8 Rx only Anti vibration Table AVT 1...

Страница 2: ...s the right to make periodic minor design changes without obligation to notify any person or entity of such change Caution Federal law restricts this device to sale by or on the order of a licensed he...

Страница 3: ...se note that only the serialized products products labelled with a distinct serial number and accessories are eligible for partial refund and or credit Non serialized parts and accessory items cables...

Страница 4: ...other than Esco Medical IN NO EVENT SHALL ESCO MEDICAL LTD BE HELD LIABLE FOR CONSE QUENTIAL DAMAGES No warranty shall apply when damage is caused by any of the following Power failure surges or spike...

Страница 5: ...original warranty covering your product becomes void when the tamper resistant Quality Seal is removed or broken without proper factory authorization In all cases breaking the tamper resistant Qualit...

Страница 6: ...AVT 1 User Manual Rev 1 8 6 COMPONENTS UNAUTHORIZED REMOVAL OF THE INSTRUMENT COVER SHALL VOID THIS AND ANY OTHER EXPRESSED OR IMPLIED WARRANTIES...

Страница 7: ...product 8 4 Accessories supplied 9 5 Safety symbols and labels 9 6 Important safety instructions and warnings 10 6 1 Before installation 10 6 2 During installation 10 6 3 Post installation 10 7 Gettin...

Страница 8: ...nance to this equipment must be un dertaken by a qualified service personnel If the equipment must be relocated make sure it is fixed properly on a support stand or base and move it on a flat surface...

Страница 9: ...s the microscope area The degree of improvement varies between instruments and locations depending on the amplitude and frequency of floor vibrations This product does not carry a CE mark Only those p...

Страница 10: ...carpet or similar surfaces 3 This unit is intended for indoor purpose only 4 Lift the device carefully All AVT 1 parts are heavy and may require additional people to move them around 5 Float elements...

Страница 11: ...le plate Figure 7 1 Leveling table legs Put on gloves Install the springs into the holes at the front and the back of the table A 3rd spring placed in the centre may be supplied for the use of a very...

Страница 12: ...tops should be facing up Leave equal distance from the hole on all sides of the table plate Then place the top of the floating element stainless steel on the rubber parts again leaving equal distance...

Страница 13: ...ween the attachment point on the microscope and the other side This can be achieved by strip ping the cable to the points and making sure that the cable forms an arch between the points If the cable i...

Страница 14: ...be in the centre position of the hole Air should be all around the floater Loose tightening bolts Tighten four tightening bolts The spring system is not painted and has to be completely grease free t...

Страница 15: ...ight 70 kg Material Powder painted mild steel Stainless steel Glass Float Size 540 340 Power consumption 115V 60Hz OR 230V 50Hz Recommended load weight 26 32 kg Damping coefficient 6 Hz 0 1 Amplitude...