Escea DX-Series Скачать руководство пользователя страница 2

A qualified installer is required to install this appliance, and, where applicable, to convert it for 
use with other gases.

This appliance must be installed in accordance with the rules in force.

If the electrical cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard.

The data label for this appliance, containing technical information and specifications, can be 
found adhered to the rear of the metal panel, under the burners on the right hand side.

DO NOT PLACE ARTICLES OR FURNISHINGS ON OR AGAINST THIS APPLIANCE.

DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IN OPERATION.

NEVER OPERATE THE FIRE IF THE GLASS HAS BEEN BROKEN OR WITH THE FRONT GLASS RE-
MOVED.

NEVER OPERATE THE FIRE WITH ANY ACCESS PANELS REMOVED.

THE APPLIANCE MUST BE INSPECTED BEFORE USE AND SERVICED AT LEAST ANNUALLY BY AN 
AUTHORISED TECHNICIAN.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN 
INSTRUCTIONS.

THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS UNLESS 
THEY HAVE BEEN ADEQUATELY SUPERVISED BY A RESPONSIBLE PERSON TO ENSURE THAT THEY 
CAN USE THE APPLIANCE SAFELY.

YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE AP-
PLIANCE.

THE GLASS SURFACE ON THE FRONT OF THE FIREPLACE IS CONSIDERED A “WORKING SURFACE” 
AND AS SUCH IS HOT AND CARE SHOULD BE TAKEN NOT TO TOUCH THIS SURFACE. IT IS RECOM-
MENDED A SECONDARY GUARD IS FITTED IN PLACE WHERE THERE ARE YOUNG CHILDREN OR 
AGED OR INFIRM PERSONS. IN GB, THIS GUARD SHOULD SATISFY THE REQUIREMENTS OF BS8423.

WARNING

!

Manufactured by:

Escea NZ Ltd

17 Carnforth st, PO Box 5277
Dunedin, New Zealand
Email: [email protected]
Web: www.escea.co.nz
Phone: +64 3 478 8220

Distributed in GB / IE by:

Urban Fires Ltd

A50, 8 Kew Bridge Road
London TW8 0FD
Tel: +44 (0)207 183 1806
Web: www.urbanfires.co.uk

The NOx class of this appliance is “NOx Class 5”

Содержание DX-Series

Страница 1: ...User Guide For the latest documentation visit www escea com 630246_3 DX Series Gas Fireplace GB IE EDITION...

Страница 2: ...CTED BEFORE USE AND SERVICED AT LEAST ANNUALLY BY AN AUTHORISED TECHNICIAN THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S WRITTEN INSTRUCTIONS THIS APPLIANCE IS NOT INTENDED FO...

Страница 3: ...On Off Button 07 7 Over Temp Shutoff Operation 07 8 Sound and Smell 08 Sounds Fan Gas Control Valve Appliance Metalwork Smells 9 Fascia Log and Glass care 09 Cleaning the logs Glass Refitting the fue...

Страница 4: ...hows temperature settings and status of timers and other functions On Off Switches the appliance on and off Flame Effect Places the fire in a constant low output mode Minus Adjusts the temperature and...

Страница 5: ...ay is show ing the desired temperature The remote will then revert back to the current room temperature after 30 seconds The lowest flame setting will run continuously whilst the medium and high setti...

Страница 6: ...r MINUS 4 button will change the hour Pressing the TIMER SELECT button 5 again will make the minute figures start flashing You will continue to see the ON and the number 1 This indicates that you are...

Страница 7: ...Overtemp Shut Off Mode To enable Overtemp Shut Off Mode so the fire will turn off the main burner when the Room tempera ture climbs above the Set temperature you need to follow the steps below to mak...

Страница 8: ...he fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Applianc...

Страница 9: ...been tested by Escea technicians and produce very satisfying results when used correctly Instructions for their use follow For Powder Coated Fascias 1 Ensure that the Gas Fireplace is off and that the...

Страница 10: ...ss and frame towards you ensuring you hold onto the glass aswell as the metal surround frame WARNING GLASS IS HEAVY AND WILL REQUIRE 2 PEOPLE AND EXTREME CARE Step 3 Take out log set if there is one a...

Страница 11: ...Crystallite Coal pieces in a single layer atop the Burners and Fuelbed Tray Cover the entire area except for the pilot shield ensuring coverage right up to both glass windows and rear of firebox for s...

Страница 12: ...to the diagram Mantles or protruding ledges above the heater must not be installed lower than the dimension shown Any curtains positioned above the appliance should not come within the dimension shown...

Страница 13: ...Flue trip The fire has tried to light three times and failed Note With this error you can im mediately try and restart again by pressing the on off button on the remote Check gas supply and check oth...

Страница 14: ...ing to restart the fireplace After restarting ensure that the duct fan is operating when the fireplace is lit and that there is air flowing from the duct outlets If there is airflow at the duct outlet...

Страница 15: ...SCEA at its sole discretion may modify adjust repair or replace the faulty products The warranty period on parts and labour shall be for twelve 12 months from the date of purchase b Labour costs will...

Страница 16: ...vered by this Limited Warranty is no longer available 6 ESCEA is not responsible for damage arising from failure to follow instructions for the product s installation maintenance and permitted and pro...