background image

8. 

Sound and Smell

Note: Each time the fire is lit from cold the glass will fog up with condensation. This is normal and the conden-

sation will disappear within a few minutes once the glass heats up.

 

− Sounds

It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the 

fact that there are various types of materials used within your appliance. Listed below are some examples. 

These are all normal operating sounds and should not be considered as defects in your appliance. 

 

− Fan:

Escea gas appliances use electric fans to push heated air further into the room. It is not unusual for the fan 

to make a “whirring” sound when ON. This sound will increase or decrease in volume depending on the 

thermostatic settings.

 

− Gas Control Valve:

As the gas control valves turn ON and OFF, a dull clicking sound may be audible. These sounds are part 

of the normal operation of the fire. When the fire is switched off after being run for a while, there may be 

popping and fluttering noises as the residual gas in the burner burns away. These are normal and should 

be no cause for concern.

 

− Appliance Metalwork:

Different types and thicknesses of steel will expand and contract at different rates resulting in some 

“creaking” and “ticking” sounds being heard throughout the heating and cool down cycles.

 

− Smells:

The first few times the unit is operated after installation, the unit may release an odour and the flames will 

appear orange caused by the curing of the paint, the burning off of the starch in the ceramic logs and the 

oils in the metal. This is a temporary curing process which will disappear with use. A deposit on the inside 

of the glass, caused by the starch in the logs may appear as a build up after several uses. If this film is not 

removed, it will bake on and may become difficult to remove. When the glass is cold, remove it (see fol-

lowing page) and clean the inside with a non-abrasive cleaner.

WARNING: DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. NEVER OPERATE THE UNIT WITH 

THE GLASS REMOVED.

Содержание DL-Series

Страница 1: ...User Guide For the latest documentation visit www escea com 630160_8 DX Series DL Series Gas Fireplace...

Страница 2: ...RE USE AND SERVICED AT LEAST ANNUALLY BY AN AUTHORISED TECHNICIAN THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S WRITTEN INSTRUCTIONS THIS APPLIANCE IS NOT INTENDED FOR USE BY...

Страница 3: ...e 05 4 Keylock 06 5 Timer Operation 06 Activate Timer De activate Timer 6 Auxiliary On Off Button 07 7 Over Temp Shutoff Operation 07 8 Sound and Smell 08 Sounds Fan Gas Control Valve Appliance Metalw...

Страница 4: ...Shows temperature settings and status of timers and other functions On Off Switches the appliance on and off Flame Effect Places the fire in a constant low output mode Minus Adjusts the temperature a...

Страница 5: ...oost DL Series ONLY The fire has four FAN SPEED settings The first low fan speed will run automatically on start up The second and third fan speed will automatically switch on or off with the increase...

Страница 6: ...r MINUS 4 button will change the hour Pressing the TIMER SELECT button 5 again will make the minute figures start flashing You will continue to see the ON and the number 1 This indicates that you are...

Страница 7: ...erature This is referred to as the Overtemp Shut Off Mode To enable Overtemp Shut Off Mode so the fire will turn off the main burner when the Room tempera ture climbs above the Set temperature you nee...

Страница 8: ...he fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Applianc...

Страница 9: ...rotective film over the fascia the entire fascia will need to be wiped to avoid seeing a difference in surface texture Ensure this film is distributed evenly 4 If the film is applied too heavily and i...

Страница 10: ...e order and test run heater 10 Trouble shooting Escea gas fires communicate both to and from the fire and remote This enables the remote to provide some basic fault finding information that is useful...

Страница 11: ...in restricted air flow at the top of the fire Room air fans may be slowed or stalled Remove firebox check that fans are plugged in cleaned and free turning The gas regulator being set too high resulti...

Страница 12: ...l and that the flue is not damaged DX Only Duct Overtemp The hot air duct temperature sensor has detected excessive heat at the duct outlet Ensure that there are at least TWO air vents installed and o...

Отзывы: