WARNING:
Before starting the installation, please
refer to the Safety Information section.
• Always switch the power off prior to beginning
the installation.
• Stainless steel is very easily damaged during
installation.
• Wherever possible, protect the rangehood with
the cardboard box or plastic.
• A power point must be located within 1.5m of
the power cord exit from the rangehood, and it
should be always accessible to allow isolation
from power during cleaning or maintenance.
• A 150mm round ducting adapter is supplied,
however all other ducting accessories are not.
• All ducting must comply with building codes and
local requirements.
• If you are re-circulating the air, rather than
ducting, please ensure that the side outlet grilles
are not obstructed in any way as this will affect
the efficiency of the rangehood.
• Ensure that the rangehood is mounted in a
level position, both horizontally and vertically.
This is essential to ensure the rangehood
operates correctly and prevents grease build
up at one end.
IMPORTANT:
Never use a silicone around
your rangehood or flue pieces. Never install the
rangehood or flue pieces into the plaster ceiling
which prevents easy access to the rangehood for
servicing requirements.
IMPORTANT:
Before installing your rangehood,
please record the details of your rangehood’s rating
label (located within the rangehood, behind the
aluminium grease filters) into the form on page 19.
This will be helpful should you need to contact our
service team in the future.
POSITIONING THE RANGEHOOD
NOTE:
When the rangehood and appliance
supplied with energy other than electricity are
simultaneously in operation, the negative pressure
in the room must be not exceed 4 Pa (4 × 10
-5
Bar).
IMPORTANT:
The height of the rangehood
underside must be a minimum of 600mm* to a
maximum 800mm from the top of your cooktop
surface (for gas cooktops this is the top of the
gas burner).
* If the installation instructions for your cooktop
specify a greater distance than the minimum, then
that shall be the minimum height for installation.
COOKTOP
FUEL TYPE:
DIMENSION A
Minimum* Maximum
Gas
(multiple burners
with maximum 45.4 MJ/h
total output and no
single burner exceeding
16.2 MJ/h output)
600mm
800mm
Gas
(multiple burners
with total output greater
than 45.4 MJ/h but less
than 77.8 MJ/h, and no
single burner exceeding
17.3 MJ/h output)
760mm
800mm
Gas
(single burner not
exceeding 21.6 MJ/h
output)
650mm
800mm
Gas
(single burner with
an output greater
than 21.6 MJ/h but not
exceeding 29.2 MJ/h)
760mm
800mm
Electric
600mm
800mm
RECIRCULATING INSTALLATION
Before beginning the installation of your rangehood,
consider your ducting method.
We recommend ducting your rangehood wherever
possible, for the maximum performance, however
this rangehood can be operated in recirculating
mode. You will need to purchase the relevant
Carbon Filter accessory which is available for
purchase from our After Sales Service Team.
If you do not have an outlet to the outside, an
exhaust pipe is not required. The rest of the
installation method is the same as Ducted
Installation.
DUCTED INSTALLATION
This rangehood has been supplied with expandable
plastic ducting, however for maximum performance
we recommend installing with rigid or semi rigid
ducting. Use cable ties or suitable duct tape to
secure the flexible pipe or ducting to the rangehood
duct outlet.