► After connecting to gas, check for leaks using soapy
solution, never a naked flame.
► Gas pressure may be checked by test point located on
regulator or LPG test point adaptor. Adjust regulator
to the required pressure as shown on data plate, check
burner ignition & and the flame is burning correctly.
► If, after installation and checking the appliance
operation, the hotplate is not working correctly,
contact the Residentia Support team on 1300 11 4357 for
assistance.
► Fit the duplicate data plate (supplied in separate bag)
on a surface adjacent to the hotplate, for example, the
inside of the cupboard door so it is clearly visible for
any service technician.
CHECKING THE GAS SUPPLY
1
Check the manometer zero point is correct.
2 Connect the manometer to the cooktop pressure point
(located on the regulator).
3 Turn on the gas supply and electricity and try to ignite
the gas burner.
Note: It will take additional time to light the gas for the
first time as air needs to be purged from the pipes.
4 With the appliance operating check the outlet pressure
► When all burners of the appliance are operating at
maximum,
► When the smallest burner of the appliance is
operating at minimum.
▷ Under these conditions the outlet pressure
should not vary from the nominal outlet
pressure of 1.00kPa by more than ±0.20kPa.
If the regulator appears to not be performing satisfactorily,
then check the following points:
1. If the outlet pressure is consistently too low then the
inlet pressure may be too low and adjustment of an
upstream regulator may be needed, or an upstream
regulator or valve with insufficient flow capacity may be
present in the gas supply line. If this is suspected then it
may be necessary to repeat the checks whilst measuring
both the inlet and outlet pressure to determine if the
inlet pressure is in the range 1.13 – 5kPa.
2. Check that the regulator has been fitted to the gas
supply line in the correct orientation, the arrow on the
base of the body indicates the direction of gas flow.
Once these checks have been completed, if the
regulator still fails to perform in a satisfactory manner
it should be replaced. Please contact the Residentia
Support Team on 1300 11 4357.