4 INSTALLATION
0463 362 001
- 11 -
© ESAB AB 2013
4.4
Mains supply
NOTE!
Mains supply requirements
This equipment complies with IEC 61000-3-12 provided that the short-circuit
power is greater than or equal to S
scmin
at the interface point between the user's
supply and the public system. It is the responsibility of the installer or user of the
equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit
power greater than or equal to S
scmin
. Refer to the technical data in the Technical
data section.
Make sure that the welding power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. A protective earth connection must be made in
accordance with regulations.
Warrior 400i CC/CV
Mains voltage
380 V 3~ 50/60 Hz
400 V 3~ 50/60 Hz
415 V 3~ 50/60 Hz
Mains cable area
4 × 6 mm²
4 × 6 mm²
4 × 6 mm²
Maximal current
rating I
max
28 A
27 A
25 A
I
1eff
MIG/MAG
TIG
MMA
20 A
16 A
21 A
19 A
16 A
20 A
18 A
14 A
19 A
Fuse
anti-surge
type C MCB
25 A
25 A
25 A
25 A
20 A
20 A
Table 1. Recommended fuse sizes and minimum cable area Warrior 400i CC/CV