4 INSTALLATION
0463 732 001
- 12 -
© ESAB AB 2020
4.3
Mains supply
NOTE!
Rogue ES 150i and ES 180i
do not comply with IEC 61000-3-12. If it is connected to
a public low voltage system, it is the responsibility of the installer or user of the
equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment may be connected.
The power source will automatically adjust to the supplied input voltage. Make sure that it is
protected by the correct fuse rating. A protective ground connection must be made, in
accordance with regulations.
1.
Rating plate with supply connection
data.
Recommended fuse sizes and minimum cable area for the Rogue ES 150i, ES 180i
Rogue ES 150i
ES 180i
Supply voltage
230 VAC
230 VAC
Electrical cable area
2.5 mm
2
2.5 mm
2
Maximal current rating
I
max
MMA/Stick (SMAW)
30 A
36 A
I1eff
MMA/Stick (SMAW)
15 A
16 A
Fuse
anti-surge type D MCB
20 A
20 A