
48
SECTION 3
INSTALLATION
3.5.1 Input Voltage Changeover - 208/230 Voltage 60 Hz UNITS ONLY
208 or 230 Mode
The PowerCut 900, 208/230 vac, 60 Hz model, is factory set for 230 vac input. If using 208 vac input, the PowerCut
900 must be reconnected as follows before connecting to your input power:
1. Remove cover.
2. Locate the Output Diode Bridge (D101) (see Figure 3.2A) on the left side towards the front panel. Disconnect
and exchange the X2 and X3 leads only. Leave other smaller wire in place. For 208 vac input, X2 is connected to
D101-2 and X3 is connected to D101-3. Ensure the connections are firmly tightened to 22 in/lbs (2.5 Nm).
3. Locate the J27 Control Supply Voltage jumper plug (violet wire) on left side towards the rear panel (see Figure
3.2b). Remove the cover plug from the J23 (208 V) header. Move J27 jumper from J20 (230 V) to J23 (208 V).
Place the cover plug on the J20 (230 V) header.
4. Reinstall cover and connect the PowerCut 900 to 208 vac input power.
ELECTrIC SHOCK CAN KILL! prECAUTIONArY MEASUrES SHOULD
BE TAKEN TO prOVIDE MAxIMUM prOTECTION AgAINST ELECTrI-
CAL SHOCK. BE SUrE THAT ALL pOWEr IS Off BY OpENINg THE LINE
(WALL) DISCONNECT SWITCH AND BY UNpLUggINg THE pOWEr
COrD TO THE UNIT WHEN rECONNECTINg fOr 208 VAC INpUT.
WArNINg
figure 3-2. Original factory Setup for 230 vac Input on
power Source with 208/230 vac, 60 Hz Input power Capability
BR102
figure 3-2b.
208 vac
figure 3-2a.
208 vac
Disconnect and exchange
the x2 and x3 leads only.
Move J27 jumper
from: J20 (230 V)
to: J23 (208 V)
Do not move this lead.
Содержание Powercut 900
Страница 17: ...17 MANUAL PLASMARC CUTTING PACKAGE Powercut 900...
Страница 18: ...18...
Страница 30: ...30 SECTION 3 INSTALLATION...
Страница 38: ...38 section 4 operation...
Страница 39: ...39 MECHANIZED PLASMARC CUTTING PACKAGE Powercut 900...
Страница 40: ...40...
Страница 57: ...57 Powercut 900 MAINTENANCE TROUBLESHOOTING SCHEMATIC DIAGRAMS REPLACEMENT PARTS...
Страница 58: ...58...
Страница 62: ...62 section 5 maintenance...
Страница 70: ...70 notes...