Страница 1: ...GB Valid from program version 1 01 0460 032 174 GB 100702 Origo TA23 Instruction manual...

Страница 2: ...IG WELDING 4 2 1 Settings 4 2 2 Symbol and Function explanations 4 2 3 Hidden TIG functions 7 3 MMA WELDING 7 3 1 Settings 7 3 2 Symbol and Function explanations 8 3 3 Hidden MMA functions 8 4 FAULT C...

Страница 3: ...mple the program version is 0 18A 1 1 Control panel TA23 Knob for setting current A or time s Display Choice of welding method TIG or MMA Choice of HF start or LiftArct Choice of 2 stroke or 4 stroke...

Страница 4: ...r source used 2 2 Symbol and Function explanations TIG welding TIG welding melts the metal of the workpiece using an arc struck from a tungsten elec trode which does not melt itself The weld pool and...

Страница 5: ...c with the LiftArc functiont Step 1 the electrode is touched on to the workpiece Step 2 the trigger switch is pressed and a low current starts to flow Step 3 the welder lifts the electrode from the wo...

Страница 6: ...panel Settings are made from the control panel Remote control unit Settings are made from the remote control unit The remote control unit must be connected to the remote control unit socket on the mac...

Страница 7: ...flows before the arc is struck Min current Used to set the minimum current for the remote control T1 Foot CAN If the max current is 100 A and the min current is to be 50 A set the hidden function min...

Страница 8: ...ltage does not exceed 35 V when welding is not being carried out This is indicated by a lit VRD LED The VRD function is blocked when the system senses that welding has started If the VRD function is a...

Страница 9: ...oming stuck S ArcPlust 0 is recommended with basic type of electrode S ArcPlustll 1 is recommended with rutile and cellulosic type of electrode Hot start Hot start increases the weld current for an ad...

Страница 10: ...serious interference on the CAN bus Action Check that there are no faulty units connected on the CAN bus Check the cables Send for a service technician if the fault persists E 14 Communication error...