© ESAB AB 2011
- 14 -
bc23de
5.6
Replacing and inserting wire
S
Open the side panel.
S
Disconnect the pressure sensor by folding it backwards, the pressure rollers
slide up.
S
Straighten out 10-20 cm of new wire. File off any burrs and sharp edges from the
end of the wire before inserting it into the wire feed unit.
S
Make sure that the wire goes properly into the feed roller track and into the outlet
nozzle and the wire guide.
S
Secure the pressure sensor.
S
Close the side panel.
6
MAINTENANCE
Regular maintenance is important for safe, reliable operation.
CAUTION
All guarantee undertakings from the supplier cease to apply if the customer attempts any
work to rectify any faults in the product during the guarantee period.
6.1
Inspection and cleaning
Power source
Check regularly that the power source is free from dirt.
The power source should be regularly blown clean using dry compressed air at reduced
pressure. This should be done more frequently in dirty environments.
Otherwise the air inlet/outlet may become blocked and cause overheating. To avoid
this you can use an airfilter.
The airfilter is an accessory. Order number can be found on page 29.
Welding gun
S
The welding gun's wear parts should be cleaned and replaced at regular
intervals in order to achieve trouble-free wire feed. Blow the wire guide clean
regularly and clean the contact tip.
The brake hub
The hub is adjusted when delivered, if
readjustment is required, follow the instructions
below. Adjust the brake hub so that wire is slightly
slack when wire feed stops.
S
Adjusting the braking torque:
S
Turn the red handle to the locked position.
S
Insert a screwdriver into the springs in the hub.
Turn the springs clockwise to reduce the braking torque
Turn the springs counter-clockwise to increase the braking torque.
NB:
Turn
both springs the same amount.
GB
Содержание ORIGO Mig C280 PRO
Страница 2: ... 2 ...
Страница 16: ... ESAB AB 2011 Diagram 16 bc23e Mig C280 380 415V ...
Страница 17: ... ESAB AB 2011 17 bc23e Mig C280 380 415V ...
Страница 18: ... ESAB AB 2011 18 bc23e Mig C280 230 500V ...
Страница 19: ... ESAB AB 2011 19 bc23e Mig C280 230 500V ...
Страница 20: ... ESAB AB 2011 20 bc23e Mig C340 380 415V ...
Страница 21: ... ESAB AB 2011 21 bc23e Mig C340 380 415V ...
Страница 22: ... ESAB AB 2011 22 bc23e Mig C340 230 500V ...
Страница 23: ... ESAB AB 2011 23 bc23e Mig C340 230 500V ...
Страница 24: ... ESAB AB 2011 Connection instruction 24 bc23c 230V 380 415V 440 460V 500V ...
Страница 30: ... 30 notes NOTES ...
Страница 31: ... 31 notes NOTES ...