-- 8 --
320e
5.5
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Rating plate with supply connection data
Origo
TM
Mig 320
3
∼
50 Hz
3
∼
50/60 Hz 3
∼
50 Hz
3
∼
60 Hz
3
∼
60 Hz
Voltage V
230
400/415
500
230
440/460
Current A
at100% duty cycle
16
9
7
16
8
at 60% duty cycle
23
14
10
23
12
at 30% duty cycle
35
20
16
34
18
Cable area mm
2
2
2
2
4 x 4
4 x 2,5
4 x 2,5
4 x 4
4 x 2,5
Fuse, slow A
20
16
16
20
16
NB:
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
GB