5 OPERATION
0459 560 101
- 11 -
© ESAB AB 2017
5.3
Fitting the central adaptor assembly to the equipment
1.
Check that the wire guide liner is fitted correctly.
2.
Insert the central plug into the socket on the wire feed unit and secure it by tightening
the adaptor nut firmly.
5.4
Setting the level of shielding gas
Set the quantity of gas required on the gas regulator. The type and quantity of gas to be used
depend on the welding task to be performed.
5.5
Checklist
Check the cable assembly before connecting it to the wire feed unit to confirm the wire liner
is suitable for the wire diameter and type.
Check the fixed end consumable parts on the swan neck, whether the correct contact tip etc.
is being used for the wire diameter and type.
5.6
Changing wire
When changing the wire, ensure that the end of the wire is deburred.
Insert the wire into the wire feeding unit in accordance with the operating instructions.
When inserting the wire, press the wire jog button on the wire feed unit.