Edition 071024
-- 11 --
smlhfpw1
DESCRIPTION OF OPERATION
LH20/1 control board
LH20/1:1 Current setting
The bandgap reference 1,23V diode V2 on LH10/2 PCB makes up a primary
voltage reference for current setting circuit and for digital meter. Current setting
reference voltage 10,7V is derived from 1,23V by the amplifier made of A2a, V30,
C14, R47, R46. The 10,7V voltage establishes reference for local current setting
potentiometer R01 as well as remote control circuitry (X02 socket).
Содержание LHF 405 PIPEWELD
Страница 7: ...Edition 071024 7 smlhfpw1 LHF 405 PIPEWELD...
Страница 10: ...Edition 071024 10 smlhfpw1 LHF 615 PIPEWELD...
Страница 19: ...Edition 071024 19 smlhfpw1 LH20 1 Components layout...
Страница 20: ...Edition 071024 20 smlhfpw1 LH10 2 Components layout...
Страница 28: ...Edition 071024 28 smlhfpw2 Assembly of components...
Страница 32: ...32 notes NOTES...
Страница 33: ...33 notes...